background image

IQEDGE

RollCall Control Panel

Issue 1 Rev 1

Page 32

© 2017 SAM

5.13 Ethernet RTP Receiver Audio Stats

The 

Ethernet RTP Receiver Audio Stats

 page displays information on the rate at which 

audio data is being received by each Ethernet port, along with an RTP discontinuity count. 
Units are megabits per second.

Click 

Enable Stats

 to display the values. These can be reset using the 

Clear All RTP Counts

 

buttons, as required.

Figure 17

 Ethernet RTP Receiver Audio Stats Page 

Содержание IQEAS00-NR

Страница 1: ...www s a m com User Manual IQEDGE 3G HD SD SDI Multi channel IP Processing System 25 40GbE...

Страница 2: ...authorized agents Reproduction or disassembly of embedded computer programs or algorithms prohibited No part of this publication can be transmitted or reproduced in any form or by any means electronic...

Страница 3: ...iertes Personal ACHTUNG Gefahr von Elektroschocks Abdeckungen nicht entfernen Keine vom Benutzer zu wartende Teile Wenden Sie sich ausschlie lich an qualifiziertes Personal L Phase N Nulleiter N Nulle...

Страница 4: ...GEN BRUGER SERVICERBARE DELE SERVICE M KUN UDF RES AF FAGL RTE PERSONER F 0 J 0 F J Han stik Hun stik F rklaring av S kerhetssymboler Denna symbol h nvisar anv ndaren till viktig information som terfi...

Страница 5: ...a menos que seja efectuadas por t cnicos habilitados Para reduzir o risco de choque el ctrico n o expor este equipamento chuva ou humidade Assegurar que a unidade est sempre devidamente ligada terra...

Страница 6: ...cording studios and the rural outdoor environment far away from railways transmitters overhead power lines etc E4 EMC Performance of Cables and Connectors Snell products are designed to meet or exceed...

Страница 7: ...7 5 2 2 Setting Values 18 5 3 Information Display 18 5 3 1 Selecting the Information to Display 18 5 4 Configuration 19 5 5 Edge Configuration 21 5 5 1 Loop Enable 22 5 6 Time Sync Configuration 25 5...

Страница 8: ...RollTrack Source 49 5 24 4 RollTrack Address 49 5 24 5 RollTrack Command 50 5 24 6 RollTrack Sending 50 5 24 7 RollTrack Status 50 5 25 Setup 51 5 25 1 Restart 51 5 25 2 Defaults 52 5 26 Ethernet Fro...

Страница 9: ...conversion including conversion aperture control Noise reduction options adaptive spatial and recursive side bar keying logo insertion and frame rate conversion Processing for 16 channels of embedded...

Страница 10: ...tus 1 3 Application Notes 1 3 1 About Power Ratings SAM IQ modules are assigned a Power Rating PR This figure represents the relative power consumption of a module SAM modular enclosures are also assi...

Страница 11: ...nels of suitable IQ processing modules so the IQEDGE lane 1 maps to the module s channel 1 and so on An IQEDGE processing lane is effectively an SDI daisy chain connected in ascending slot number orde...

Страница 12: ...AN00 RP for additional cooling IQEDGE 40 12B IQEDGE 14 Slot 3RU IP processing system with quad 40GbE IP connections Up to 8 card slots for processing available Includes dual PSUs dual fans Ethernet SN...

Страница 13: ...IQEDGE Introduction Issue 1 Rev 1 Page 13 2017 SAM 1 6 Rear Panel View The following rear panel types are available Figure 2 IQEDGE25 6B3 Figure 3 IQEDGE40 6B3...

Страница 14: ...RFC3190 SMPTE 291M IETF RTP Payload for Ancillary Data VC 2 IEEE 1588v2 SMPTE 2059 2 VSF TR 03 TR 04 RTP upgradeable to SMPTE 2110 or SMPTE 2022 6 7 AES67 Note For information on IQH3B and IQH4B enclo...

Страница 15: ...15 2017 SAM 3 Connections This section describes the physical input and output connections provided by the IQMIX IP transceiver modules 3 1 25G Ethernet SFP 3 2 40G Ethernet QSFP SFP supporting 25G E...

Страница 16: ...rails use an LED e g 7v5 other power rails used on the module e g 3v3 5v0 etc also use an LED 6 14 5 13 4 12 3 11 PTP Green PTP Locked flashes at 1s 1 8 Input port status 9 16 Output port status Green...

Страница 17: ...page view list allowing quick access to any of the pages 5 2 1 Template Pages The following pages are available Configuration See section 5 4 Edge Configuration See section 5 5 Time Sync Configuration...

Страница 18: ...tings within the templates have values either alpha or numeric When setting a value in a field the value whether text or a number must be set by pressing the ENTER key or clicking the Save Value butto...

Страница 19: ...is page Figure 6 Configuration Page Option Operation Where Am I Causes the front edge LEDs to flash allowing the module to be easily identified Genlock Select Genlock type Network click to use a netwo...

Страница 20: ...hange Interface Configuration Displays the IP address for each of the Ethernet interfaces Card Firmware Software Version Each software version contains multiple firmware images different images are su...

Страница 21: ...ows the card slots controlled by the EDGE backplane to be monitored and the modules to be used in a workflow specified The page consists of two sections one for Lane 1 and one for Lane 2 These display...

Страница 22: ...disable IP routing for slots 1 and 2 and cause daisy chains to be created from Slot 1 to Slot 2 and from Slot 2 to Slot 3 As Loop Enable has not been selected for Slot 3 IP routing remains in place an...

Страница 23: ...he instructions in the examples above Open the Edge Configuration page and navigate to the appropriate Slot Map entry In the diagram above this would be Slot 3 Lane 1 We can see that the IP input for...

Страница 24: ...017 SAM Enter the IP details noted in the step above and click S to save As Loop Enable has not been selected for Slots 3 and 6 IP routing remains in place and so the signal will be routed across lane...

Страница 25: ...ace Click check boxes to select the required network interface PTP Configuration Select values from the PTP Domain and PTP Delay Request Frequency drop down lists as required Type the appropriate IP n...

Страница 26: ...ator allows a caption to be overlaid on the video essence Figure 11 TPG Page Option Operation TPG Select the test pattern to apply to the spigot from the drop down list Audio Freq Select the audio fre...

Страница 27: ...EDGE RollCall Control Panel Issue 1 Rev 1 Page 27 2017 SAM 5 8 Counters The Counters page allows the various counters provided to be cleared down Click Clear buttons as required Figure 12 Counters Pag...

Страница 28: ...lows a static IP address to be defined Enter information as required then click S to save New settings are applied when Restart is clicked The following options are also available 5 9 2 The All Traffi...

Страница 29: ...Page 29 2017 SAM 5 10 Ethernet 1 and 2 RTP Sender The RTP Sender page displays the amount of data transmitted on a spigot by spigot basis Units are megabits per second Click Enable Stats to display va...

Страница 30: ...eceiver page displays the amount of data received plus details of packet loss on a spigot by spigot basis Units are megabits per second Click Enable Stats to display the values These can be reset usin...

Страница 31: ...Stats page displays information on the rate at which video data is being received by each Ethernet port along with an RTP discontinuity count Units are megabits per second Click Enable Stats to displa...

Страница 32: ...Stats page displays information on the rate at which audio data is being received by each Ethernet port along with an RTP discontinuity count Units are megabits per second Click Enable Stats to displa...

Страница 33: ...Stats page displays information on the rate at which metadata is being received by each Ethernet port along with an RTP discontinuity count Units are megabits per second Click Enable Stats to display...

Страница 34: ...ontrol The Link Control page allows quad link 4K inputs to be synchronized To have the system synchronize quad link inputs enable the check box next to the set of inputs to synchronize To use 4K SMPTE...

Страница 35: ...age 35 2017 SAM 5 16 Destination Timing The Destination Timing page allows genlock timing on each spigot to be adjusted in order to synchronize the IP signal with the house reference Make adjustments...

Страница 36: ...the associated BNC connector and the overall module status The following controls are also available Disable Extended Headers extended header operation can be disabled for TR 03 TR 04 compatibility E...

Страница 37: ...e defined for the selected spigot Stats for the spigot can also be enabled from here To set multicast details Enter IP and port details as required Select the appropriate flow type from the Flow Type...

Страница 38: ...audio delay for the spigot Make Break Mode Specifies how changes to an input s source will be made Make before Break causes the new source to buffer data before connection to the previous source is br...

Страница 39: ...e check boxes that correspond to the parameters for which log information should be collected Log Field Displays the name of the logging field Log Value Displays the current log value The information...

Страница 40: ...columns Log Enable Select the check boxes that correspond to the parameters for which log information should be collected Log Field Displays the name of the logging field Log Value Displays the curren...

Страница 41: ...restart in the format ddd hh mm ss RC_UPTIME ROL_STATES Displays the RollCall status Valid values are OK FAIL n where n is the RollTrack index or indices which are failing Disabled REAR_ID Displays th...

Страница 42: ...VG_DELAY Displays time sync average delay in nS TIMESYNC_N_STDV_DELAY Displays time sync Standard Deviation delay in nS TIMESYNC_N_AVG_ERROR Displays time sync average error in nS TIMESYNC_N_STDV_ERRO...

Страница 43: ...of traffic received by the Ethernet port Values are reported in Kbps Mbps or Gbps as appropriate LAN_PORT_N_TRAFFIC_OUT Displays speed of traffic transmitted by the Ethernet port Values are reported i...

Страница 44: ...collected Log Field Displays the name of the logging field Log Value Displays the current log value The information below describes the various parameters available for logging Figure 25 Logging SFP...

Страница 45: ...GE_N_NAME Displays voltage sensor name VOLTAGE_N_VALUE Displays current voltage reading VOLTAGE_N_STATE Displays temperature sensor state Valid values are OK WARN Low Low but in tolerance WARN High Hi...

Страница 46: ...ameters for which log information should be collected Log Field Displays the name of the logging field Log Value Displays the current log value The information below describes the various parameters a...

Страница 47: ...nput Where N is the input number Figure 27 Logging Spigot n Page Log Field Description INPUT_N_IDENT Displays a system defined identifier for the input based on the rear ID INPUT_N_NAME Displays name...

Страница 48: ...s total amount of CPU memory available to the module in bytes TOTAL_USED_MEMORY Reports amount of CPU memory used by the module in bytes NUM_CORE_DUMPS Reports number of times a core dump has been per...

Страница 49: ...Dragging the slider selects the RollTrack source displayed below the slider Clicking P selects the default preset value When no source is selected Unused is displayed Where N is the input number 5 24...

Страница 50: ...is the value sent with the RollTrack command 5 24 6 RollTrack Sending A message is displayed here when the unit is actively sending a RollTrack command Possible messages are 5 24 7 RollTrack Status A...

Страница 51: ...icture Figure 30 Setup Item Description Product Name of the module Software Version Currently installed software version number Firmware Version Currently installed firmware version number Serial No M...

Страница 52: ...required 5 26 1 The Ethernet Pane The Ethernet pane displays details of the currently selected network interface and allows a static IP address to be defined Enter information as required then click...

Страница 53: ...anel Issue 1 Rev 1 Page 53 2017 SAM 5 27 Ethernet Arcnet Not currently used 5 28 Interop Page The Interop page allows the VC2 compression rate to be set Select as required Figure 32 Ethernet Arcnet Pa...