IQEDGE
RollCall Control Panel
Issue 1 Rev 1
Page 41
© 2017 SAM
OS_VERSION=
Displays the operating system name and version.
BUILD_NUMBER=
Displays the build number.
HARDWARE_VERSION=
Displays the hardware version number.
HARDWARE_MOD=
Displays the hardware modification number.
HARDWARE_BUILD=
Displays the hardware build number.
FEATUREBOARD_VERSION=
Displays the featureboard version number.
FEATUREBOARD_MOD=
Displays the featureboard modification number.
FEATUREBOARD_BUILD=
Displays the featureboard build number. Valid values are:
•
FB1
•
FB2
FIRMWARE_VERSION=
Displays the firmware version number.
UPTIME=
Displays the time since the last restart in the format
ddd:hh:mm:ss
.
RC_UPTIME=
ROL_STATES=
Displays the RollCall status. Valid values are:
•
OK
•
FAIL:n
where
n
is the RollTrack index or indices
which are failing
•
Disabled
REAR_ID=
Displays the code number of the rear fitted.
REAR_STATUS=
Displays the status of the rear where it can be
determined.
SLOT_WIDTH=
Displays the slot width. IQMIX modules are available in
single and double width.
SLOT_START=
Displays the slot in the rack where IQMIX is located.
POWER_USAGE=
Displays the power usage in Watts/Load Units.
TEMP_N_CELSIUS=
Displays system temperature in °C. Note this item is
critical and cannot be disabled.
TEMP_N_NAME=
Displays temperature sensor name.
REFERENCE_N_SOURCE=
Displays reference type. Valid values are:
•
Lock to Input
•
Ext Ref
•
PTP
•
NTP
•
Frame Ref A
•
Frame Ref B
•
WARN:Freerun
•
WARN:Unknown
Log Field
Description