![Snap-On ControlTech CTLNK1R240 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/snap-on/controltech-ctlnk1r240/controltech-ctlnk1r240_manual_1307353007.webp)
Torque and Angle Mode Cycle Counting
1.
Numerical counter located in top right of target torque or target angle screen will increment after each
torque or angle cycle if applied torque or angle has reached target value.
2.
When toggling between torque mode or angle mode using ENTER button or if target is changed, numerical
counter will reset back to 00. Counter WILL NOT reset when re-zeroing, on menu entry/exit or power down.
3.
Memory icon will turn on ONLY when the wrench is used while the controller either out of range or turned
off.
Main Menu
Main menu displays wrench operational information.
1.
From target torque or angle screen, press and hold ENTER button for 3 seconds.
2.
Use UP/DOWN buttons to highlight menu selection then press ENTER button.
Menu Selections:
EXIT - Exits Main menu and returns to target screen.
LANGUAGE - Displays language selection menu.
SET HEAD LENGTH - Displays wrench head length entry screen.
SHOW DATA - Displays stored torque and angle data.
CLEAR DATA - Clears stored torque and angle data.
CYCLE COUNT - Displays torque/angle cycle count screen.
SETTINGS - Displays advanced settings menu (see Advanced Settings Section).
CONFIGURE - Displays advanced configuration menu (see Advanced Configuration Section).
3.
To select language menu, press ENTER button while
LANGUAGE
is highlighted then highlight desired
language and press ENTER button.
4.
Decimal Mark selection menu is displayed. Decimal separator can be a comma or decimal point. Use
UP/DOWN buttons to select decimal separator then press the ENTER button.
Note: Decimal separator will affect formatting of downloaded data when opened by Excel depending on
Windows® regional settings.
5.
To exit Main menu and return to target torque or angle screen, press ENTER button while
EXIT
menu
selection is highlighted.
Decimal Mark Selection menu
DECIMAL MARK
COMMA (1,23)
POINT (1.23)
ENTER
button
UP/DOWN buttons
DECIMAL MARK
COMMA (1,23)
POINT (1.23)
00
100,0
FT-LB
ENTER button
00
100.0
FT-LB
EXIT
LANGUAGE
SET HEAD LENGTH
SHOW DATA
ENTER
button
held
Target Screen
Main menu
ENGLISH
FRANCAIS
ESPANOL
DEUTSCH
ENTER
button
Language Selection menu
Содержание ControlTech CTLNK1R240
Страница 1: ...ControlTech LINK Wireless ELECTRONIC TORQUE ANGLE WRENCH 20 3104 SO REV B 21 11 ...
Страница 33: ...This page intentionally left blank ...
Страница 34: ......
Страница 35: ......