Adding a Torque Preset
1.
From manual target torque screen, select units of measure.
2.
Press and hold UNITS button for 3 seconds.
3.
ADD PRESET confirmation screen is displayed. Highlight
YES
menu selection using UP/DOWN
buttons then press ENTER button.
NO
menu selection returns to main menu without adding
a PSET.
4.
TARGET TORQUE screen is displayed. TARGET TORQUE is target value of fastener. Initial
TARGET TORQUE value is value from target torque screen. TARGET TORQUE can be set to
any value within wrench torque range by pressing UP/DOWN buttons. Once desired target
torque value has been set, press ENTER button.
5.
MINIMUM TORQUE screen is displayed. MINIMUM TORQUE is value at which green progress
lights, audible alert and vibrator turn on. Initial MINIMUM TORQUE value is TARGET TORQUE
value minus negative torque tolerance (default 0%, see MODE SETUP in Advanced
Configuration section). MINIMUM TORQUE can be set to any value from TARGET TORQUE to
wrench minimum torque range by pressing UP/DOWN buttons. Once desired minimum
torque value has been set, press ENTER button.
6.
MAXIMUM TORQUE screen is displayed next. MAXIMUM TORQUE is torque value above
which red progress lights turn on. Initial MAXIMUM TORQUE value will be TARGET TORQUE
value plus positive torque tolerance (default 4%, see MODE SETUP in Advanced
Configuration section). Maximum torque value can be set greater than TARGET TORQUE
value to 10% above wrench maximum range by pressing UP/DOWN buttons. Once desired
maximum torque value has been set, press ENTER button.
7.
BATCH COUNT screen is displayed next. Default value is zero. Batch count range is 0 to 99.
Press UP/DOWN buttons to increment/decrement batch count. Mode Count increments
each time target torque is reached if a batch count of zero is entered. Mode Count
decrements if a non-zero batch count is entered and resets to batch count value when count
reaches zero. Once desired batch count value has been set, press ENTER button.
8.
PSET target screen is displayed labeled with next available PSET number from 01 to 50.
9.
To enter additional torque presets, repeatedly press ENTER button until target torque screen
is displayed and repeat steps above.
MAXIMUM
TORQUE
104.0
FT-LB
UP/DOWN buttons
ENTER
button
BATCH COUNT
3
ENTER
button
UP/DOWN buttons
ADD PRESET
YES
NO
ADD PRESET
YES
NO
00
100.0
FT-LB
UNIT
button
held
Target Torque Screen
ENTER
button
UP/DOWN buttons
UP/DOWN buttons
ENTER
button
ENTER button
TARGET TORQUE
100.0
FT-LB
MINIMUM
TORQUE
100.0
FT-LB
PSET 01
01of03
100.0
FT-LB
Preset Torque Screen
UP/DOWN buttons
ENTER button