38
With this software version, by pressing remote control buttons A,B,G,H,I the corresponding exits will be
activated provided that the contacts of the mechanical limit switches are closed.
Exit
Mechanical limit
switches
Operation
EV1
MEC. EV1
EV1 activated only if MECH. EV1 contact is closed (red LED rouge ON).
EV3
MEC. EV3
EV3 activated only if MECH. EV3 contact is closed (red LED rouge ON).
EV5
MEC. EV5
EV5 activated only if MECH. EV5 contact is closed (red LED rouge ON).
EV7
MEC. EV7
EV7 activated only if MECH. EV7 contact is closed (red LED rouge ON).
POMPE
MEC. EV1 – MEC.EV3
MEC. EV5 – MEC. EV7
Is activated only if at least one of the EV exits is enabled.
CONNECTING UP BLACK BOX
Connect the 1 mm
2
red wire to the ignition key (+15 V) by means of a 500 mAF fuse.
In this way, if any LED (EV 1-EV 2 etc.) is activated by a limit switch (connected to the RXVESNS-05 control unit),
the corresponding LED and buzzer will be activated.
The red LED lights up and the buzzer sounds when the ignition key is turned with one or more limit switches having
their contact closed and connected to earth.
N.B.: Carry out periodic check up on the good working order of the buzzer and corresponding LEDs
DASHBOARD CONTROLLER – SMALL BLACK BOX
CONTROLLER OPERATION WITH MECHANICAL LIMIT SWITCHES
Switch on the control box (ON) with the vehicle parked: the red LED will not light up and the buzzer will not sound.
(If the same operation is carried out with the engine switched on, the red LED will light up and the buzzer will sound
until the engine is switched off).
When the ignition key is turned for driving the vehicle, if a jack is not in the correct position, the red LED will light up
and the buzzer will sound.
When driving, the control unit must be switched to OFF and the +15 (D+) under key
controller will verify the limit switch status.
BEFORE DRIVING CHECK THAT ALL THE JACKS ARE RETRACTED IN THE
DRIVING POSITIO
+12-VOLT red under key wire
BLACK WIRE WITH TELEPHONE
JACK TO RECEIVER
WARNING
CHECK JACKS
Содержание MULTI-LIFT SYSTEM
Страница 22: ...22 SIMPLIFIED ELECTRIC DIAGRAM ...
Страница 24: ...24 DOUBLE EFFECT TELESCOPIC JACKS ...
Страница 25: ...25 DOUBLE EFFECT EASYHUB ...
Страница 26: ...26 HEAVY JACKS ...
Страница 28: ...28 HYDRAULIC TUBE FITTING ...
Страница 29: ...29 HYDRAULIC SCHEME ...
Страница 30: ...30 CONNECTING HYDRAULIC TUBES ...
Страница 32: ...32 DIMENSIONS ...
Страница 49: ...49 5 6 7 8 3 5 4 5 6 ...
Страница 53: ...53 ...