BREAKDOWN
PROBABLE CAUSES
POSSIBLE SOLUTIONS
Pump does not supply
the required flow
- blocked filter
- disassemble and clean (or replace)
- air intake in the suction tube
- Check closure grip
-Collector leakage caused by fusion defect
-Replace collector
- Breakage of coupling for pump-motor
- Disassemble and replace
connection
- Damage to pump-collector connection gasket - Disassemble collector pump and replace
gasket
- Worn out pump
- Replace
Pump does not supply
the right pressure
- Calibration error on pressure relief valve
- Re-set required calibration
(calibration too low)
Pump does supply
the right pressure
- Worn out pump
- Replace
- Insufficient motor power
- Assemble more powerful motor
- Excessive loss of charge in circuit
- Check for possible bottlenecks
or excessive oil viscosity
Pump does not supply
the right pressure
- Leakage from the valves
- Check that the valves are tightened
Valve blockages
or leakages
- Leakage -
check valve
- Disassemble and blow
(replace if necessary)
- Electric seat valve leakage
- Disassemble and blow
(replace if necessary)
- Electric valve excitation faulty
- Check that the minimum required voltage is
reaching the bobin
Minimum required voltage
(90% of normal voltage)
- Blockage of slide valve caused by
- Disassemble and blow
Dirt in the circuit
(replace if necessay)
- Try to add filtering elements to the
circuit, to obtain better filtering (25 micron)
Содержание MULTI-LIFT SYSTEM
Страница 22: ...22 SIMPLIFIED ELECTRIC DIAGRAM ...
Страница 24: ...24 DOUBLE EFFECT TELESCOPIC JACKS ...
Страница 25: ...25 DOUBLE EFFECT EASYHUB ...
Страница 26: ...26 HEAVY JACKS ...
Страница 28: ...28 HYDRAULIC TUBE FITTING ...
Страница 29: ...29 HYDRAULIC SCHEME ...
Страница 30: ...30 CONNECTING HYDRAULIC TUBES ...
Страница 32: ...32 DIMENSIONS ...
Страница 49: ...49 5 6 7 8 3 5 4 5 6 ...
Страница 53: ...53 ...