37
Each time a remote control button or a manual switch on the control panel is pressed, the corresponding solenoid valve
as well as the pump will be enabled.
7) Close the waterproof case using the two remaining screws.
8) Install the inductive and mechanical sensors onto the hydraulic jacks.
-
Connect the inductive and mechanical sensors with the connection cables supplied and insert the connectors into
the sockets located in the lower part of the power pack following the sequence.
OPERATION OF MECHANICAL SWITCHES
When the contact of one or more mechanical sensors (MEC. EV 1-2 – MEC. .EV 3-4 – MEC. EV 5-6 – MEC. EV 7-8) is
closed, the corresponding red light on the control unit will light up. Operation can be carried out using the remote control
only if the contact of the corresponding limit switch is closed (red LED on). N.B.: it is always possible to operate manually
whether the red LED is on or off.
OPERATION WITH “BLACK BOX”
Mechanical sensors: the red LED of the black box and the corresponding buzzer are only activated when the ignition key of
the vehicle is turned and if the contact of one or more mechanical limit switches is closed. The buzzer will stop and the red
LED will turn itself off only if the vehicle ignition key is removed (the positive pole of the black box is powered by this
key), or if the contacts are open (all red LEDS off). The red LED and buzzer on the black box can be activated by the
mechanical limit switches even if the control unit switch is in the OFF position.
After use, always switch the control unit switch to the OFF position.
OPERATION OF SECURITY RELE’
Every time the ignition key is turned, the security relè installed on board cut the alimentation to the control unit (when the
igation is activated and the motor of the vehicle runs all the controls are switched OFF, we can’t use our level system).
9) After use, always switch the control unit switch to the OFF position.
OPERATING THE REMOTE CONTROL
The remote control has
twelve
keys. The following procedure is used to control the
8 solenoid valves
, individually,
in pairs etc.
Remote control
Button
Operation
Remote control
Button
Operation
A
EV 1
A + B
EV 1 + EV 3
B
EV 3
D + E
EV 2 + EV 4
D
EV 2
G + H
EV 5 + EV 7
E
EV 4
L + M
EV 6 + EV 8
G
EV 5
A + G
EV 1 + EV 5
H
EV 7
B + H
EV 3 + EV 7
I
EV 1 + EV 3 + EV 5 + EV 7
D + L
EV 2 + EV 6
L
EV 6
E + M
EV 4 + EV 8
M
EV 8
C
Emergency- Remote control suspends all
operations and control unit will not
work with remote control
N
EV 2 + EV 4 + EV 6 + EV 8
F
Autolevel Button
Содержание MULTI-LIFT SYSTEM
Страница 22: ...22 SIMPLIFIED ELECTRIC DIAGRAM ...
Страница 24: ...24 DOUBLE EFFECT TELESCOPIC JACKS ...
Страница 25: ...25 DOUBLE EFFECT EASYHUB ...
Страница 26: ...26 HEAVY JACKS ...
Страница 28: ...28 HYDRAULIC TUBE FITTING ...
Страница 29: ...29 HYDRAULIC SCHEME ...
Страница 30: ...30 CONNECTING HYDRAULIC TUBES ...
Страница 32: ...32 DIMENSIONS ...
Страница 49: ...49 5 6 7 8 3 5 4 5 6 ...
Страница 53: ...53 ...