36
EV1, EV2 CONTROL THE FRONT LEFT JACK.
EV3, EV4 CONTROL THE FRONT RIGHT JACK.
EV5, EV6 CONTROL THE BACK LEFT JACK.
EV7, EV8 CONTROL THE BACK RIGHT JACK.
3) CONNECT THE NUMBER-CODED CABLES TO THE J2 TERMINAL BOARD
There is a small bridge on the J3 terminal board. If necessary, connect a key switch or remote switch, eliminate
the bridge and connect the two 2.5 mm
2
section wires.
4) Connect the solenoid valve control and power 12/24V cables as follows:
- Connect the number-coded caps to the corresponding solenoid valves.
- Connect the faston terminals labelled «POMPA» (PUMP) to the remote control switch of the pump.
- Connect the cable with a yellow grommet (
Ø
8mm) labelled «MASSA» (EARTH) to the earth.
- Connect the cable with a yellow grommet (Ø8 mm) labelled «+12/24V» to the power supply
BA12/24V (B12/24V).
5)
Insert two nylon screws in the lower holes of the control unit cover and screw tighten them in the holes at the
base of the waterproof case so as to be able to use them as hinges. At this point, insert the J1 female connector
into the corresponding male connector located on the printed circuit.
6)
Program the remote control combination and the operating time as follows :
- Turn on the unit by means of the power switch (ON).
- Press the black programming button located on the back of the printed circuit, then release it.
- Press the button corresponding to the operating time limit that you wish to set once (see table below)
- Wait until the “RICEZIONE” (“RECEIVER”) LED turns itself off and then turns itself on again, then press
the same button again.
- Turn off the device and then turn on again to check that programming has been carried out correctly.
If programming has not been carried out correctly, repeat procedure from point 6.
It is also possible to set a time lapse in which the device remains operative from the time it is switched on or from the
last remote control button pressed, as indicated in the table below.
Button
A
B
D
N
E
G
I
H
L
C-F-M
Time
(minutes)
1
10
15
20
30
45
60
120
180
No time
limit
EXAMPLE A
If button
B
is pressed during the programming phase, the unit will remain operative for 10 minutes from when it is
switched on or from the last time the button was pressed.
EXAMPLE B
If button
C
is pressed during the programming phase
,
the control unit will remain continuously operative.
Once the pre-programmed time has elapsed, it will no longer be possible to operate any of the solenoid valves by means
of the remote control, they can only be operated using the switches on the control panel. It is strongly recommended
that you set an operating time limit to avoid accidental or unintentional operation of the remote control which could
result in damage to people or objects. When the «ricezione» (“reception”) led on the unit is off, it cannot be operated by
remote control. To re-set, lower the main switch to the OFF position and after a few seconds turn the switch back to the
ON position.
Содержание MULTI-LIFT SYSTEM
Страница 22: ...22 SIMPLIFIED ELECTRIC DIAGRAM ...
Страница 24: ...24 DOUBLE EFFECT TELESCOPIC JACKS ...
Страница 25: ...25 DOUBLE EFFECT EASYHUB ...
Страница 26: ...26 HEAVY JACKS ...
Страница 28: ...28 HYDRAULIC TUBE FITTING ...
Страница 29: ...29 HYDRAULIC SCHEME ...
Страница 30: ...30 CONNECTING HYDRAULIC TUBES ...
Страница 32: ...32 DIMENSIONS ...
Страница 49: ...49 5 6 7 8 3 5 4 5 6 ...
Страница 53: ...53 ...