Your SPYDERCRANE
’
s Safeties and Operator Aids
Operator Aids (continued)
System
Description
Turnover Prevention Device
(URW306
-
T ONLY)
The Turnover Prevention Device (TPD) is a system of load cells and a centralized computer (the TPD
Amplifier) that monitors the stability of the SPYDERCRANE and can activate a CMU CODE 15 FKO
when it detects that it is nearing its stability limits (do to overloading, or boom movement).
Visual Warning Systems
System
Description
Outrigger Mode Indicator
The Outrigger Mode Indicator is the yellow lamp located on the top of the Operator Station and it lights up
when the SPYDERCRANE is placed into Outrigger Mode.
Remote Control Indicator
The Remote Control Indicator is the orange lamp located on the top of the Operator Station and it lights up
when the SPYDERCRANE is placed into Remote Control.
Run Indicator
The Run Indicator is the green tower lamp that strobes whenever the SPYDERCRANE is running.
The Run
Indicator is only installed on 095
-
/200
-
Series SPYDERCRANEs equipped with the 110V Battery
-
Electric
powerpack.
Radio Remote Receiver
Status Panel
Located on outward facing panel of the Radio Remote Receiver (bolted to the rear of the Hydraulic Oil
Tank), the Status Panel is a series of red and green LEDs that can be used to troubleshoot problems with
TPD Amplifier Status Pan-
el
Located on the outward facing panel of the TPD Amplifier (located inside the Operator Station and viewa-
ble through a sheet metal cutout), the Status Panel is a series of orange, green and red LEDs that can be
used to troubleshoot problems with the Turnover Protection Device (TPD).
The TPD is only installed on 095
-
/200
-
Series SPYDERCRANEs.
Unlike the audible alarms and warning systems, the visual warning indicators and lamps CANNOT be turned off.
Audible Alarms and Warning Systems
System
Description
Safety Horn
The Safety Horn is used to warn bystanders and can be activated from:
The Safety Horn Button in the Travel Control Group (next to the Ignition Switch).
The Safety Horn Button in the Outrigger Control Group (next to the Crane/ Outrigger Mode Toggle).
The Remote Safety Horn Button on the Remote Controller.
Voice Mute Switch
The voice mute switch, when set to the OFF position turns off the audible signals from the voice warning sys-
tems and audible alerts system.
The voice mute switch does not affect audible signals from the LMI, the TPD, or the outrigger mode alarm.
Outrigger Buzzer
Mute Switch
This is a mute switch specifically for the outrigger mode alarm.
TPD Alarm Mute
The TPD alarm mute is an on/off toggle used to mute the alarms associated with the TPD.
While all of the audible alarms and indicators can be switched off, doing so WILL reduce your situational awareness. Audible alarms and
indicators should ONLY be turned off when the SPYDERCRANE is being operated where noise controls are in effect.