ALARM ID
DESCRIPTION
USER ACTION
A-:69
P2 can empty
As for “A-:68”
A-:70
P3 can empty
As for “A-:68”
AF:73
Internal memory data storage
error
For the user: follow the
DEFAULT PROCEDURE
described above.
If the alarm does not disappear, follow the
RESET PROCEDURE.
AF:74
Water leak from chamber. Alarm
only enabled with the Aquastop
accessory fitted.
Turn off the water supply taps.
Contact the After-Sales Service.
AF:75
No salt in softener. This alarm
does not appear on the Display but
is recorded in the appliance
memory; the relative LED
illuminates on the display.
Add salt to the softener salt tank inside the chamber, accessible
with the door open.
AF:77
Intake water temperature over
45°C; prewash temperature must
be below 45°C. Alarm generally
disabled on GW series products.
The alarm occurs when the temperature is over 45°C at the start
of the cycle.
Wait for the appliance to cool before starting a new cycle.
AF:78
Restore fail
. Problem of
motherboard.
For the user: follow the
DEFAULT PROCEDURE
described above.
If the alarm does not disappear, follow the
RESET PROCEDURE.
AF:79
Program not compatible.
This alarm is triggered if a program is created using the WD-
TRACE software using procedures not compatible for the proper
performance of the cycle. Reconsider the program created phase
by phase; it may be useful to compare it with an original Smeg
program provided as reference (see attached PROGRAMS TABLE
doc.).
Pay special attention to the version of the appliance being used;
e.g. do not activate peristaltic pump P3 when writing the
program if this pump is not installed.
AF:84
Dryer temperature reading higher
than actual temperature. (Only on
GW4060).
Wait for the alarm to be resolved automatically.
During automatic management of the AF:84 alarm the RESET
cycle cannot be started.
Do not disconnect the electricity supply to the device: the
overheating problem is being dealt with automatically, with a
heating element cooling cycle.
The
DEFAULT PROCEDURE
described above cannot be
implemented until the end of the automatic process.
AF:91
Internal memory full.
This alarm only occurs if the appliance parameter that prevents
overwriting in the memory is enabled.
With the default setting, this alarm will not occur.
Memory space must be cleared to allow use of the appliance:
this can be done by connecting to the appliance by means of the
RS-232
serial port and using the Smeg
WD-TRACE
software.
AF:92
Drying filter maintenance
The absolute filter in the drying system has exceeded the set
number of working hours. Contact the After-Sales Service to
have the filter changed. The filter is a consumable and is not
covered by the warranty.
Press the
Start/Stop
button to override the message and
continue using the device.
The device’s internal memory records the event.
With a fouled filter, drying will be poor.