5.4
“CLOC” – DATE AND TIME PARAMETERS
The
Cloc
parameter (an abbreviation of “
CLOCK”
),
is used to
modify the current date and time
.
This parameter can be modified with just the user password.
The modification procedure is:
1.
To select the
Cloc
parameter, hold pressed the
Start/Stop
button (3) when the indication
“Cloc” is
on the
display (ref. also to the par . “
ACCESSING THE SETUP MODE”
).
2.
Selection
buttons (4-8): for modifying the value of the parameter.
3.
Functions
button (5) – quick press
:
to move from one parameter to the next. (on GW4060 the operator can
also use the “
”
key (6) with the same function).
4.
Start/Stop
button (3): hold pressed to confirm the modification
5.
Door opening
button (7): hold pressed to quit the parameter being modified and the Cloc function.
During modification, the parameter concerned flashes.
CLOC PARAMETER
DESCRIPTION
C1
Year, last two figures only (00-99), e.g.: for “2012” enter “12”
C2
Month (1-12)
C3
Day (1-31)
C4
Hour (1-24)
C5
Minutes (0-59)
C6
Seconds (0-59)
fig. 32 –
Cloc
parameters. Hold down the
Start/Stop
button to access the parameters, in this case identified as
C1, C2, etc.
Parameter
C1
sets the
current year,
C2
the month, etc. Use the
Selection
buttons to modify the parameter. Use the “
Functions”
button to move to another parameter.
Confirm changes using the
Start/Stop
button.