Auto-preset 

When auto-preset is selected in function selection mode, the set value can be calculated and memorized 
from the measured pressure.

 

Repeating the suction and release of the workpiece to be set for several 

times will automatically optimize the set value. 

 

 

(1) Selection of auto-preset OUT1 mode 

Press the SET button in measurement mode to display [AP1 rEdY]. 
(If setting of OUT1 is not necessary, select [AP1 rEdY], and then press the 
UP and DOWN buttons simultaneously for 1 second or longer. 
The display will move to (4) Selection of auto-preset OUT2 mode.) 

 

(2) Preparation of equipment for OUT1 

Prepare the equipment for which the pressure of OUT1 is to be set. 

 

(3) Setting of auto-preset for OUT1 

Press the SET button, [AP1 rUn] will be displayed. 
Measurement starts. Operate the device to change the pressure. 
(If the UP and DOWN buttons are pressed simultaneously for 1 second 
or longer while [AP1 rUn] is displayed, measurement will be stopped 
and (4) Selection of auto-preset OUT2 mode will return.) 

 

(4) Selection of auto-preset OUT2 mode 

Press the SET button in measurement mode to display [AP2 rEdY]. 
(If setting of OUT2 is not necessary, select [AP2 rEdY], and then press the 
UP and DOWN buttons simultaneously for 1 second or longer. 
The display will move to measurement mode.) 

 

(5) Preparation of equipment for OUT2 

Prepare the equipment for which the pressure of OUT2 is to be set. 

 

(6) Setting of auto-preset for OUT2 

Press the SET button, [AP2 rUn] will be displayed. 
Measurement starts. Operate the device to change the pressure. 
(If the UP and DOWN buttons are pressed simultaneously for 1 second 
or longer while [AP2 rUn] is displayed, measurement will be stopped 
and measurement mode will return.) 

 

(7) Complete setup. 

Press the SET button to complete auto-preset mode. Then, measurement mode returns. 

 

The settings in auto-preset will be as follows. 

•Normal output 

•Reversed output 

P_1(P_2)=A-(A-B)/4 

n_1(n_2)=B+(A-B)/4 

A = Maximum pressure 

H_1(H_2)=

(A-B)/2

 

H_1(H_2)=

(A-B)/2

 

B = Minimum pressure 

 

 

If setting is not necessary press the UP and DOWN buttons simultaneously for 1 second or longer. 

Содержание PSE20 A Series

Страница 1: ...No PS OMW0005 A PRODUCT NAME Multi channel Digital Sensor Monitor MODEL Series Product Number PSE20 A...

Страница 2: ...range display unit 31 F 1 Setting of OUT1 37 F 2 Setting of OUT2 40 F 3 Digital filter setting 42 F 4 Auto preset function 43 F 5 Auto shift setting 45 F 6 Fine adjustment of display value 47 F10 Sub...

Страница 3: ...equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly T...

Страница 4: ...the failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excl...

Страница 5: ...ful fluids Fire malfunction or damage to the product can result Verify the specifications before use Do not operate in an atmosphere containing flammable or explosive gases Fire or an explosion can re...

Страница 6: ...esign and selection installation wiring environment adjustment operation maintenance etc described below must also be followed Product specifications Use the specified voltage Otherwise failure or mal...

Страница 7: ...e power is on Otherwise damage to the internal parts can result causing malfunction Do not route wires and cables together with power or high voltage cables Otherwise the product can malfunction due t...

Страница 8: ...rate close to a heat source or in a location exposed to radiant heat Otherwise malfunction can result Adjustment and Operation Turn the power on after connecting a load Otherwise it can cause excess c...

Страница 9: ...or sensor lead wire ZS 28 C 1 pc Panel mount adapter ZS 26 B With set screw M3 x 8L 2 pcs and waterproof seal Panel mount adapter Front protective cover ZS 26 C With set screw M3 x 8L 2 pcs and waterp...

Страница 10: ...nd sets a set value Unit display Red Green Lit ON the indicator of selected unit For the Controller without unit selection function the unit is fixed to SI MPa kPa or Pa Unit label Attach the unit lab...

Страница 11: ...d value for sharp start up or fall of the pressure When the function is valid digital filtering is reflected to the ON OFF of the switch output Output chattering or flicker in the measurement mode dis...

Страница 12: ...e of the product The resistance between the electrical circuit and the case K Key lock function Function that prevents changes to the settings of the product disables button operation M Manual setting...

Страница 13: ...rent Ideally should be 0 V Resolution Refer to Display resolution Reversed output One of the switch output types In hysteresis mode the switch output is turned ON when pressure less than or equal to t...

Страница 14: ...over Model ZS 26 01 48 conversion adapter Model ZS 26 D The panel mount adapter can be rotated by 90 degrees for mounting Front panel of this Controller meets IP65 if 48 conversion adapter is used it...

Страница 15: ...r can be removed from facility after removing two screws as shown in a figure by making insert the suitable thin card for the hook of both the sides pull a panel mount adapter to the front and remove...

Страница 16: ...tor size mm2 Overall diameter mm Colour of cover SMC product No 1 pc 26 24 28 0 14 0 2 0 08 0 8 to 1 0 Red ZS 28 C 1 0 to 1 2 Yellow ZS 28 C 1 1 2 to 1 6 Orange ZS 28 C 2 22 20 0 3 0 5 1 0 to 1 2 Gree...

Страница 17: ...necting the connector insert it straight onto the pin and lock the connector into the square groove in the housing until connector clicks When removing the connector press down the lever with your thu...

Страница 18: ...wire Model ZS 26 L is used the colours of wire Brown Blue White Gray Red Green Yellow will apply as shown on circuit diagram PSE200A M NPN open collector 5 outputs Auto shift 1 input Max 30 V 80 mA Re...

Страница 19: ...ed off The default setting is that the output is turned ON at 50 5 kPa when the pressure range of the connected sensor is vacuum Perform initial setting by referring to the setting outline page 19 Zer...

Страница 20: ...mately 3 sec after supplying power After that measurement mode is displayed Within approximately 0 2 second after power on the switch starts Initial Setting Function selection mode F 0 Refer to page 2...

Страница 21: ...n 3 and 5 sec Press the DOWN button once 3 step setting mode Set either of set value or hysteresis Refer to page 25 Simple setting mode Select the set value hysteresis and delay time Refer to page 27...

Страница 22: ...Press the SET button Differential pressure check mode setting Setting common for all channels Set and display the differential pressure between CH1 CH2 and CH3 CH4 Press the UP button to select the di...

Страница 23: ...it Press the SET button to set Other than USEr is selected Press the SET button to move on to display unit setting Move on to the setting of the lower limit of the additional rated range The lower lim...

Страница 24: ...e that is required to be displayed when the sensor input signal is 100 The setting range is 1500 to 1500 digit There is unsettable range Refer to page 36 Press the SET button to set Move on to display...

Страница 25: ...essure check mode pressure range and display unit is completed Press the SET button for 2 second or longer Measurement mode Initial setting is completed Perform the setting with the 3 step setting mod...

Страница 26: ...ss the SET button once when the item to be changed is displayed on the sub display The set value on the sub display right will start flashing 2 Press the UP or DOWN button to change the set value The...

Страница 27: ...on and WH1 WH2 hysteresis following the instructions given on page 25 When reversed output is selected the sub display left shows n1L n2L and n1H n2H Please refer to the List of output modes on page 3...

Страница 28: ...ress the SET button to set the value Then the setting moves to the delay time of the switch output The snap shot function can be used Refer to page 66 4 The delay time of the switch output can be sele...

Страница 29: ...he upper limit of the switch operation WH1 WH2 hysteresis and dt1 dt2 delay time following the instructions given on page 27 When reversed output is selected the sub display left shows n1L n2L and n1H...

Страница 30: ...hese settings To change a setting enter function selection mode F 0 Differential pressure check mode pressure range and display unit Page 31 Item Default setting Differential pressure check mode OFF C...

Страница 31: ...Select the display colour Output ON Green Output OFF Red Linked to OUT1 Other parameter settings Item Page Default setting F 3 Digital filter setting Page 42 0 00 sec F 4 Auto preset function Page 43...

Страница 32: ...ode is selected the range of the sensor connected to CH1 CH2 and CH3 CH4 should be the same Initial range setting rAnG and unit setting Unit and digital filter FiL for CH2 and CH4 are not selectable T...

Страница 33: ...l range USEr Input value setting Input value setting Available display unit and minimum set value Pressure range Rated pressure Display MPa kPa Pa kgf cm2 bar mbar psi inHg mmHg mmH2O Fine differentia...

Страница 34: ...hannels Set and display the differential pressure between CH1 CH2 and CH3 CH4 Press the UP button to select the differential pressure check mode Press the SET button Move on to pressure range setting...

Страница 35: ...it Press the SET button to set Other than USEr is selected Press the SET button to move on to display unit setting Move on to the setting of the lower limit of the additional rated range The lower lim...

Страница 36: ...nsor input signal is 100 The setting range is 1500 to 1500 digit There is unsettable range Refer to page 36 Press the SET button to set Move on to display unit setting Display unit setting Press the U...

Страница 37: ...ble unit Udot 0 002 0 02 0 2 2 When pressure range minimum unit lower limit upper limit of additional range is changed setting below will be initialized and cleared These items must be set again Displ...

Страница 38: ...o output mode setting Output mode setting Press the UP or DOWN button to select the required output mode Press the SET button to set Move on to reversed output setting Reversed output setting Press th...

Страница 39: ...erring to the setting method on page 27 Press the SET button to set Move on to display colour setting Display colour setting Press the UP or DOWN button to select the display colour Press the SET butt...

Страница 40: ...e switch output changes is outside of the set pressure range due to the selection of normal or reversed output the hysteresis value is automatically adjusted The figure above shows an operation at OUT...

Страница 41: ...ting Press the UP or DOWN button to select the required output mode Press the SET button to set Move on to reversed output setting Reversed output setting Press the UP or DOWN button to select the rev...

Страница 42: ...e setting method on page 27 Press the SET button to set Move on to display colour setting Display colour setting common setting for F 1 Press the UP or DOWN button to select the display colour Press t...

Страница 43: ...ET button Move on to digital filter setting Digital filter setting Press the UP or DOWN button to select the digital filter The digital filter can be set in the range 0 00 to 30 0 sec in increments of...

Страница 44: ...lection mode to display F 4 Press the SET button Move on to Auto preset function Auto preset function Press the UP or DOWN button to select the auto preset function Press the SET button to set Return...

Страница 45: ...urement will be stopped and 4 Selection of auto preset OUT2 mode will return 4 Selection of auto preset OUT2 mode Press the SET button in measurement mode to display AP2 rEdY If setting of OUT2 is not...

Страница 46: ...flow from the reference value Operation Press the UP or DOWN button in function selection mode to display F 5 Press the SET button Move on to the setting of auto shift Auto shift setting Press the UP...

Страница 47: ...be corrected to the upper or lower value whichever is closer The correction is performed when the auto shift input is applied at the pressure beyond the set pressure range If the auto shift input is a...

Страница 48: ...r DOWN button in function selection mode to display F 6 Press the SET button Move on to fine adjustment of display value Fine adjustment of display value Press the UP or DOWN button to change adjustme...

Страница 49: ...name displayed on the sub display Press the SET button to make the next digit to the right flash Input the line name The most significant digit flashes when the SET button is pressed at the least sign...

Страница 50: ...ion displays the items and values on the sub display The displayed item varies depending on the setting of the output mode Select the displayed items by pressing the DOWN button in measurement mode Hy...

Страница 51: ...ode is selected Set value for OUT2 hysteresis mode When hysteresis mode is selected OUT2 hysteresis mode When hysteresis mode is selected OUT2 Window comparator mode set value Lower side When window c...

Страница 52: ...ror output Normal Reversed output Switch output off When using the 2 value display function 3 step setting is not available for the display When setting 3 step select each set value to be displayed by...

Страница 53: ...The threshold bar will not be displayed Only the pressure value meter is displayed Output mode Output style Threshold bar display style Hysteresis mode Normal output Reversed output Window comparator...

Страница 54: ...d pressure or Character string display Function to display the specified character string on the sub screen When line name is input characters which can be displayed for each digit are as follows Disp...

Страница 55: ...n Press the SET button to set Return to function selection mode F11 Display resolution setting completed The display resolution is not possible to be selected while setting the additional range It may...

Страница 56: ...n selection mode to display F14 Press the SET button Move on to select zero cut off setting Select zero cut off setting Press the UP or DOWN button to select the value of zero cut off The display abov...

Страница 57: ...saving mode Setting common for all channels Press the UP or DOWN button to select the power saving mode Press the SET button to set Return to function selection mode F80 Power saving mode completed In...

Страница 58: ...cking Security code checking Press the UP or DOWN button to input the security code on the sub display right The default setting is 000 For instructions on how to enter the security code refer to How...

Страница 59: ...sing the SET button for 1 second At this point the changing of the security code is not completed Return to the change of setting again by pressing the UP or DOWN button Press the SET button for 1 sec...

Страница 60: ...of functions Return to oFF not used then press the SET button to set Return to function selection mode F90 Setting of all functions completed Setting of each function Every time the SET button is pre...

Страница 61: ...of OUT2 11 Reversed output setting of OUT2 12 Pressure setting of OUT2 13 Hysteresis setting of OUT2 14 Delay time setting of OUT2 15 Display colour setting 16 Digital filter setting 17 Auto preset f...

Страница 62: ...the right Channel from which a copy is made of the currently selected channel Displayed in the the sub screen on the left When changing the channel to be copied change the channel in measurement mode...

Страница 63: ...UP or DOWN button in function selection mode to display F96 Press the SET button Sensor input External input signal status display Select to display the sensor input or external input signal condition...

Страница 64: ...on to output check Output check Press the UP or DOWN button to select output check n Normal output is selected Press the SET button to set Return to function selection mode F Forced output is selected...

Страница 65: ...o select OUT1 output check Press the SET button to set OUT1 output check CH4 Press the UP or DOWN button to select OUT1 output check Press the SET button to return to n normal output then press the SE...

Страница 66: ...de to display F99 Press the SET button Move on to reset to default settings Reset to default settings Press the UP or DOWN button to display ON then press the SET and DOWN buttons simultaneously for 5...

Страница 67: ...indow comparator mode Set value Hysteresis Set value The value is set to the same value as the display value current pressure value There is a range which cannot be set to the current pressure dependi...

Страница 68: ...Key lock function The key lock function is used to prevent errors occurring due to unintentional changes of the set values If the SET button is pressed while the keys are locked LoC is displayed on th...

Страница 69: ...C or UnLoC will be displayed on the sub display 2 Select the un locking UnLoC with UP or DOWN button Setting is recognized by pressing the SET button then security code is required 3 For instructions...

Страница 70: ...the SET button to make the next digit to the right flash If the SET button is pressed at the last digit the first digit will start flashing After the setting is complete Press and hold the SET button...

Страница 71: ...tting LoC or UnLoC will be displayed on the sub display Press the UP and DOWN buttons simultaneously for 5 second or longer Press the SET and DOWN buttons simultaneously for 5 second or longer Display...

Страница 72: ...t installation etc Please consult SMC Yes No The sensor monitor does not operate normally Refer to Trouble No 1 The switch output does not turn OFF The operation light is ON The switch output generate...

Страница 73: ...ect Refer to Trouble No 9 Refer to Trouble No 9 Refer to Trouble No 11 The display is missing Refer to Trouble No 10 The display accuracy does not meet the specifications Refer to Trouble No 12 The di...

Страница 74: ...eck if PNP output is used when NPN should have been selected or the other way around Revise the model selection output specification Lead wire broken Check if there is bending stress applied to any pa...

Страница 75: ...er limit HHH 1 Check if the pressure exceeds the upper limit of the set pressure range 2 Check if foreign matter has entered the piping 1 Reset applied pressure to a level within the set pressure rang...

Страница 76: ...part of the lead wire 1 Check and correct the wiring 2 Correct the wiring bend radius and stress 11 Pressure display is unstable when products are in close proximity to each other Variation within th...

Страница 77: ...not work Key lock mode is activated Check if the key lock function is turned on Check the key lock function Product failure Replace the product 15 The operation is unstable chattering Effect of line...

Страница 78: ...econd later The zero clear range varies by 1 F S due to variation between individual products Release the applied pressure to atmospheric pressure and retry the zero clear operation Pressurizing error...

Страница 79: ...plied voltage NPN output 30 VDC Internal voltage drop Residual voltage 1 5 V or less Load current 80 mA Delay time 2 5 ms or less variable from 0 to 60 s 0 01 s increments Hysteresis Variable from zer...

Страница 80: ...e units selection function Only MPa kPa or Pa is available for models without this function 5 The response time indicates when the set value is 90 in relation to the step input 6 When 48 mm conversion...

Страница 81: ...80 No PS OMW0005 A Dimensions Power supply output cable ZS 26 L...

Страница 82: ...4 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the...

Отзывы: