Summary of Product parts
○Names of individual parts
Output display (Orange): Lit when OUT1 (CH1 to CH4) and/or OUT2 (only CH1) is ON.
Main display (Red/Green): Displays the current status of pressure, setting mode, selected indication unit
and error code.
UP button: Selects the channel and mode, and increases the ON/OFF set value.
DOWN button: Changes the sub display, selects the mode and decreases the ON/OFF set value.
SET button: Changes the mode and sets a set value.
Unit display (Red/Green): Lit ON the indicator of selected unit. For the Controller without unit selection
function, the unit is fixed to SI (MPa, kPa or Pa).
Unit label: Attach the unit label (kgf/cm
2
, bar, psi, inHg, mmHg, Pa, mbar, mmH
2
O) with a unit selection
function.
LCD of corresponding unit turns on as follows:
When MPa is selected
When kPa is selected
When kgf/cm
2
is selected
When bar is selected
When psi is selected
When unit other than above is selected
Channel display (Orange): Indicate the CH1 to CH4 that is selected at that time.
Sub display (left) (Orange): Displays items.
Sub display (right) (Orange): Displays set values, peak and bottom values.