-32-
No.PS
※※
-OMW0005-A
Pressure range setting
Pressure range that matches with the connected sensor can be selected.
In addition, the required range can be set and displayed. (Additional range)
●
Relation between the sensor input and pressure display
Pressure range
Set value
A
B
Fine differential pressure
0.002
0 kPa
2 kPa
Vacuum pressure
- 0.1
0 kPa
-101 kPa
Compound pressure
F0.1
-100 kPa
100 kPa
Low pressure
0.1
0 kPa
100 kPa
Positive pressure
0.5
0 kPa
500 kPa
1.0
0 MPa
1 MPa
1.6
0 MPa
1.6 MPa
High pressure
2.0
0 MPa
2 MPa
5.0
0 MPa
5 MPa
10.0
0 MPa
10 MPa
20.0
0 MPa
20 MPa
25.0
0 MPa
25 MPa
Additional range
USEr
Input value (setting)
Input value (setting)
●
Available display unit and minimum set value
Pressure range
Rated
pressure
Display
MPa
kPa
Pa
kgf/cm
2
bar
mbar
psi
inHg
mmHg mmH
2
O
Fine differential pressure
2 kPa
0.002
-
0.001
1
-
-
0.01
0.001
-
-
0.1
Vacuum pressure
-101 kPa
- 0.1
0.001
0.1
-
0.001
0.001
-
0.01
0.1
1
-
Compound pressure
±100 kPa
F0.1
0.001
0.1
-
0.001
0.001
-
0.02
0.1
1
-
Low pressure
100 kPa
0.1
0.001
0.1
-
0.001
0.001
-
0.01
-
-
-
Positive pressure
500 kPa
0.5
0.001
1
-
0.01
0.01
-
0.1
-
-
-
1 MPa
1.0
0.001
1
-
0.01
0.01
-
0.1
-
-
-
1.6 MPa
High pressure
2 MPa
2.0
0.001
1
-
0.01
0.01
-
0.2
-
-
-
5 MPa
5.0
0.01
-
-
0.1
0.1
-
1
-
-
-
10 MPa
10.0
0.01
-
-
0.1
0.1
-
1
-
-
-
20 MPa
20.0
0.01
-
-
0.1
0.1
-
2
-
-
-
25 MPa
25.0
0.02
-
-
0.2
0.2
-
2
-
-
-
Additional range x 1
USEr
It varies depending on the minimum unit setting of the additional range.