![SMC Networks LECPMJ Series Скачать руководство пользователя страница 79](http://html1.mh-extra.com/html/smc-networks/lecpmj-series/lecpmj-series_operation-manual_1299638079.webp)
- 78 -
(7) Check that data is being transmitted and the transmission is completed by using the same procedures
described in (3) and (4).
When data transmission is completed, [Position] of the step data No. 1 is output to the remote register
RWr6 to 7: DATA.
RWr6
:
DATA (H)
=
(0000)h
RWr7
:
DATA (L)
=
(1388)h
(8) Check that step data has been edited correctly. To end the data editing function, turn OFF the remote
registerRWw0,bit1: Parameter rewrite flag.
For the memory address used in the data editing function in the full numeric data instructions mode, please
check
"10.2 Remote register (RWr and RWw)".
Input
Start flag
DATA(H,L)
Output
24V
0V
ON
OFF
・
・
・
・
ON
OFF
・
・
・
・
Power
Sending
Sending completed
Setting parameter
rewriting
Data
(SubFunction etc)
(2)
(3)
(4)
(1)
(5)
(6)
(7)
(8)
Min 15ms
Min 15ms