- 56 -
1
F to 0
L
Current position
The current position of the electric actuator is
shown in multiples of 0.01 mm when numerical
data reading is enabled.
Example)
800.00mm (80000d
=
13880h) is output:
RWr1
=
3880h
RWr2
=
0001h
2
F to 0
H
3
7 to 0
L
R
et
urn
of
D
at
a
ed
iti
n
g
Sub
Function
Current speed
● Half numerical data instructions
The executed instruction code is output. Please
refer to
“9.5 Data editing function"
for details
of the instruction code. The value of 80h that is
the OR (logical add) is output to Sub Function
which set in RWw1.
*3)
● Full numerical data instructions
The current speed of the electric actuator is
shown in multiples of 1 mm/s when numerical
data reading is enabled
Example) 300 mm/s (300d=012Ch) is output
RWr3
=
012Ch
F to 8
H
4
7 to 0
L
Address
Current Force
● Half numerical data instructions
The start address of the executed instruction
code is output. Please refer to
“9.5 Data editing
function"
for details of the instruction code
00h is output in abnormal conditions.
*3)
● Full numerical data instructions
The current pushing force of the electric actuator
is shown in multiples of 1% when numerical data
reading is enabled.
F to 8
H
5
F to 0
L
Address
(always 0)
Target position
● Half numerical data instructions
0 is always output.
● Full numerical data instructions
The target position of the electric actuator is
shown in multiples of 0.01 mm when numerical
data reading is enabled.
6
F to 0
H
DATA (H)
● Half numerical data instructions
Data that corresponds to the executed
instruction code is output.
An error code is output when there is an
abnormality.
● Full numerical data instructions
The target position of the electric actuator is
shown in multiples of 0.01 mm when numerical
data reading is enabled.