![SMC Networks LECPMJ Series Скачать руководство пользователя страница 109](http://html1.mh-extra.com/html/smc-networks/lecpmj-series/lecpmj-series_operation-manual_1299638109.webp)
- 108 -
● Full numerical data instructions (4 Stations occupied) [Remote register]
PLC memory
address
RWr Data name
PLC memory
address
RWw Data name
RWr
bit
Numerical
data
instructions
operation
Data editing
RWw
bit
Numerical data
instructions
operation
Data editing
0
0
Return of Occupied number of
stations (L)
0
0
Setting read numerical data
1
Return of Occupied number of
stations (H)
1
Setting parameter rewriting
2
Sending
2
Reset flag
3
Sending completed
3
Restart flag
4
READY
4
Movement MOD
Start flag
5
ALARM flag
5
Speed
(No used)
6
Initial
6
Position
7
Return of the read numerical data
7
Acceleration
8
Return of parameter rewriting
8
Deceleration
9
(No used)
9
Pushing force
A
A
Trigger LV
B
B
Pushing speed
C
C
Moving force
D
Data editing error receiving
D
Area 1
E
Parameter anomaly detection
E
Area 2
F
The abnormal station detection
F
In position
1
F to 0
Current position
1
0
Start flag
Sub Function
7 to 1
(No used)
F to 8 Movement MOD
2
F to 0
2
F to 0
Speed
Address
3
F to 0
Current speed
3
F to 0
Target position
Address
(always 0)
4
F to 0
Current Force
4
F to 0
DATA (H)
5
F to 0
Target position
5
F to 0
Acceleration
DATA (L)
6
F to 0
6
F to 0
Deceleration
Occupation area
7
7 to 0
Alarm 1
7
F to 0
Pushing force
F to 8
Alarm 2
8
7 to 0
Alarm 3
8
F to 0
Trigger LV
F to 8
Alarm 4
9
F to 0
Occupation
area
Sub Function
9
F to 0
Pushing speed
10
F to 0
Address
10
F to 0
Moving force
11
F to 0
Address
(always 0)
11
F to 0
Area 1
12
F to 0
DATA (H)
12
F to 0
13
F to 0
DATA (L)
13
F to 0
Area 2
14
F to 0
Occupation
area
14
F to 0
15
F to 0
15
F to 0
In position