- 95 -
LESH
Basic parameter default
LESH
Return to origin parameter default
Model
LESH8
LESH16
LESH25
Lead[mm]
4
8
5
10
8
16
B
as
ic
p
aram
ete
r d
efa
u
lt
Controller ID
1
1
1
IO pattern
1
1
1
Acceleration /
Deceleration pattern
1
1
1
S-motion ratio
0
0
0
Storoke (+)
S1
S1
S1
Storoke (-)
-1.00
-1.00
-1.00
Maximum speed
200
400
200
400
150
400
Maximum acceleration/
deceleration
5000
5000
5000
Default In position
0.50
0.50
0.50
ORIG offset
0.00
0.00
0.00
Max force
70
70
70
Para protect
1
1
1
Enable SW
2
2
2
Unit name
Part no. of each product
W-AREA1
0.00
0.00
0.00
W-AREA2
0.00
0.00
0.00
ORG Correct
0.00
0.00
0.00
Sensor type
1
1
1
Option set1
1
1
1
Undefined parameter11
1
1
1
Undefined parameter12
1
1
1
Model
LESH8
LESH16
LESH25
Retu
rn t
o o
rigi
n p
aram
ete
r de
fa
ul
t
ORIG direction
2
2
2
ORIG mode
1
1
1
ORIG limit
100
100
100
ORIG time
100
100
100
ORIG speed
20
20
20
ORIG ACC / DEC
100
100
100
Creep speed
10
10
10
ORIG sensor
0
0
0
ORIG SW Dir
0
0
0
Undefined parameter21
0
0
0