![SMC Networks LECPA Series Скачать руководство пользователя страница 66](http://html.mh-extra.com/html/smc-networks/lecpa-series/lecpa-series_operation-manual_1299839066.webp)
- 65 -
12.2 Alarm details
Alarm
(code)
G
rou
p
How to
deactivate
Alarm contents/ Countermeasure
Step data
ALM1
(1-048)
B
RESET
SVON
input
<Contents>
The step data is in-correct for the following conditions:(Assignable value
range)
(1) Area1 < Area2
(If both Area1 and Area2 is 0, the alarm will not be activated.)
(2) Trigger LV ≤ Pushing force
(When the pushing force is 0, the alarm will not sound even if Pushing
force < Trigger LV)
(3) Minimum speed of the
electric
actuator ≤ Pushing speed ≤ Speed
(4) Pushing speed ≤ Maximum pushing speed of the
electric
actuator
(5) Pushing force ≥ Minimum pushing force of the
electric
actuator
(6) Basic parameters “Max force” ≥ Minimum pushing force of the
electric
actuator
(7) Basic parameters “Max force” ≥ Trigger LV
(8) Pushing force ≠ 0
<Countermeasure>
Modify the step data and basic parameters setting.
Caution
Please confirm this pushing force and minimum speeds of Data
maximum speed and 0 or more of the
electric
actuator with the
electric
actuator manual or the catalog.
Parameter
ALM
(1-049)
B
RESET
SVON
input
<Contents>
The basic parameter is not correct for the following condition: (Assignable
value range)
(1) Stroke (-) < Stroke (+)
(2) W-Area 1 < W-Area2
(If both W-Area1 and W-Area2 is 0, the alarm will not be activated.)
(3) Maximum pushing force < Maximum pushing force of
electric
actuator
<Countermeasure>
Modify the basic parameter setting.
Caution
Please refer to the manual or the catalogue of the
electric
actuator for
the max/ min pushing force/ speed for the
electric
actuator.
Step data
ALM2
(
1-051
)
B
RESET
SVON
input
<Contents>
Generated when test operation is performed by the teaching box or
Controllersetting kit.
<Countermeasure>
(1) Check if "Operation" of the step data is "Blank (Invalid data)".
(2) This product cannot perform test operation by the teaching box or
Controller setting kit. Refer to
“7.1 Step data”.