![SMC Networks LECPA Series Скачать руководство пользователя страница 71](http://html.mh-extra.com/html/smc-networks/lecpa-series/lecpa-series_operation-manual_1299839071.webp)
- 70 -
13. Wiring of cables/Common precautions
Warning
1. Adjusting, mounting or wiring change should never be done before shutting off the power
supply to the product.
Electrical shock, malfunction and damaged can result.
2. Never disassemble the cable. Use only specified cables.
3. Never connect or disconnect the cable or connector with power on.
Caution
1. Wire the connector securely. Do not apply any voltage to the terminals other than those
specified in the product Manual.
2. Wire the connector securely.
Check for correct connector wiring and polarity.
3. Take appropriate measures against noise.
Noise in a signal line may cause malfunction. As a countermeasure, high voltage and low voltage
cables should be separated, and keep wiring lengths short, etc.
4. Do not route wires and cables together with power or high voltage cables.
The product can malfunction due to interference and surge voltage cables. Route the wires to the
product separately from power or high voltage cables.
5. Take care that electric actuator movement does not damage cables.
6. Fix cables securely so that they do not move easily. Avoid bending cables at sharp angles
where the cables enter the product.
7. Avoid twisting, folding, rotating or applying an external force to the cable.
Risk of electric shock, wire break, contact failure and lost of control for the product can happen.
8. Fix the motor cable protruding from the product in place before using.
The motor and lock cables are not robotic type cables and can be damaged when moved.Therefore
do not place A part below it in a flexible moving tube.
9. Select “Robotic type cables” when deflecting actuator-cables repeatedly. Do not put cables into
a flexible moving tube with a radius smaller than the specified value (minimum 50mm).
Risk of electric shock, wire break, contact failure and loss of control for the product can happen if
“Standard cables” are used in case of inflecting the cables repeatedly.
10. Confirm proper wiring of the product.
Insulation failure (interference with other circuit, poor insulation between terminals, etc.) could
introduce excessive voltage or current to the driver or its peripheral devices and damage them.
11. The Speed / pushing force may vary, depending on the cable length, load and mounting
conditions etc..
If the cable length exceeds 5m, the speed / pushing force will be reduced by a maximum of 10% per
5m. (If the cable length is 15m: Maximum 20% reduction.)