- 32 -
Solenoid Valve Stop Time
Interlocked with the IO-Link parameter.
Set the function to prevent overdrive of the
solenoid valve when the supply pressure is
insufficient.
No
Key operation
LED Display
(1)
Deactivate the key lock if necessary (see page 22).
(2)
Press S-key for 2 seconds or more, then go to detail setting mode.
(3)
To "F12" by using the
△
and
▽
keys.
⇔
(displayed alternately)
(4)
Press S-key.
(5)
Set Solenoid Valve Stop Time by using
the
△
and
▽
keys.
(number changes)
※
Setting range : refer to Note 1
(6)
Press S-key.
⇔
(displayed alternately)
(7)
Press S-key for 2 seconds or more, then go out from detail setting mode.
(Select the menu with
△
or
▽
keys, then jump to another item.)
(8)
Activate the key lock if necessary (see page 22).
(
Note1
)
:
The setting range of Solenoid Valve Stop Time is 0 to 99 (in percent units).
The relationship between the LED display by key operation and Solenoid Valve Stop Time is as
follows.
LED
表示
Solenoid Valve Stop Time
[% of 100 seconds]
0
0
1
1
99
99
※
is the factory default value.
If the Solenoid Valve Stop Time is set, it will
Stops the operation of the solenoid valve.
The longer the set Solenoid Valve Stop Time, the longer the stop time of solenoid valve
operation.
If the Solenoid Valve Stop Time is 0 (factory default), the function is disabled
.
※