![SMC Networks ITV2050-IL20-X399 Series Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/smc-networks/itv2050-il20-x399-series/itv2050-il20-x399-series_operation-manual_1299596019.webp)
- 18 -
Parameter index
0x49 (Notification setting of accumulated energizing time)
Parameter name
Notification setting of the accumulated energizing time
Function
This function uses process data to notify the user that the accumulated
energizing time of the electro-pneumatic regulator reached the time set
with this function.
The default value is "0," which means no notification is output.
If a value is "1" or greater, the notification setting is enabled.
Bit
Bit 31 to 0
0
Value
Setting the Bit to 1111 1111 1111 1111 1111 1111 1111 1111 sets it to
approximately 4 billion hours.
Setting the Bit to 0000 0000 0000 0000 0010 0010 0011 1000 sets it
to approximately 8,760 hours (equivalent to 1 year: 24 hours x 365
days).
* The default value is "0," which means that the notification is disabled.
Parameter index
0xA0 (Product number)
Parameter name
Product number
Function
Displays the product number of the electro-pneumatic regulator.
Bit
BYTE 64 (Maximum)
Value
The Bits 49 54 56 32 30 35 30 2D 49 4C 33 30 2D 31 2D 4B 2D 58 33
39 39 (hexadecimal number) indicate "ITV2050-IL30-1-K-X399."
(ASCII code)