![SMC Networks ITV2050-IL20-X399 Series Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/smc-networks/itv2050-il20-x399-series/itv2050-il20-x399-series_operation-manual_1299596030.webp)
- 29 -
Zero clear
This function is the same as the function via IO-Link.
The display can be set to zero again by executing "zero clear".
When "zero clear" is executed with residual pressure in the secondary piping, the pressure is
assumed to be zero. Please execute the operation of "zero clear" with the supply pressure is
intercepted, and the piping of the second side removed.
No
Key operation
LED Display
(1) Deactivate the key lock if necessary (see page 22).
(2) Press S-key for 2 seconds or more, then go to detail setting mode.
(3) To "F03" by using the
△
and
▽
keys.
⇔
(displayed alternately)
(4) Press S-key.
flashes on the display
(5)
Press
△
and
▽
keys for 3 seconds or more.
(press S-key to (3))
is displayed
(6)
"Zero clear" is executed, after 3 seconds.
(Release keys till less than 3 seconds to (4))
is displayed for approx. 1
second.
(7)
Returns to the state immediately after turning on of the power supply.
Activate the key lock if necessary (see page 22).
(note)
:
The adjustable range is within ±5%F.S from the state of the factory shipment. When more
than this range,
is displayed and zero-clear is not executed.