- 21 -
Setting using buttons
!
Caution
(1) If the incorrect key is pressed or incorrect information is displayed during setting, power
must be shut off and the procedure started again.
(2) When you press the S key after completing the value setting for operation mode and
standby mode, the operation will start immediately, so be careful when doing so. We
recommend operation without supply pressure.
(3) Even if no signal is input, if pressure is supplied to the primary side, the pressure set in
each mode will be output to the secondary side, so be careful. However, please note that for
the NO type, when the power is turned off, the pressure equal to the supply pressure minus
0.1 MPa will be output.
(4) Output pressure from this product and state of operation are changed by changing of each
setting and function. Each setting and function should be operated by trained and
experienced operator.
(5) Do not configure settings using the button operation and IO-Link communication at the
same time. If settings are made by both methods, unintended settings may be configured.
Flow of the setting
*Only when the key lock is active
POWER ON
UNLOCK KEYS
LOCK KEYS
RESET
SETING NOMAL MODE
SETING STANDBY MODE
DETAIL SETING
GAIN
SENSITIVITY
ZERO CLEAR
INITIALIZE
REFER TO P22
REFER TO P23
REFER TO P22
REFER TO P24
REFER TO P26 TO P29
Pressure display unit
Pressure Ramp Up Duration
SOLENID VALVE
STOP TIME
(Note 1): Please refer to each contents about operation method.