![SMC Networks ITV2050-IL20-X399 Series Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/smc-networks/itv2050-il20-x399-series/itv2050-il20-x399-series_operation-manual_1299596013.webp)
- 12 -
Key-lock:
Performs the key lock using button operation.
When the keys are locked, setting changes or restoration by data storage (rewriting of
parameter settings) through communication can still be performed.
Lock the data storage:
ITV data storage function” is disabled by locking the “Data storage”.
In this case, access is rejected for data storage backup (reading of parameter settings) and
restoration (rewriting of parameter settings).
Device status parameter (Index:0x24)
Readable device status is as follows.
Data type: 8-Bit UInteger
Value
Definition of status
Details
0
operation
-
1
Maintenance is required
Notification is occurring
2
Out of spec.
Warning
3
Check the functionality.
Not supported.
4
Failure
Abnormal
Device details status parameter (Index:0x25)
Event details of the readable device status are as
follows.
Subindex
Event
Event class
Event code
Definition
Value
1
EEPROM error
Error
0xF4
0x1810
2
Internal system error
Error
0xF4
0x1811
3
Built-in solenoid valve error
Error
0xF4
0x1812
4
Internal communication error
Error
0xF4
0x1813
5
Excessive power supply voltage
error
Warning
0xE4
0x5110
6
Low power supply voltage error
Warning
0xE4
0x5111
7
Pressure value over range error
Warning
0xE4
0x8c10
8
Pressure value under range
error
Warning
0xE4
0x8c30
9
Target value over range error
Warning
0xE4
0x1820
10
Residual pressure error
Warning
0xE4
0x1821
11
Notification of the accumulated
energizing time reached
Notification
0x54
0x1830
12
Pressure setting error
notification
Notification 0X54
0x1831