State
⑥
: Since the temperature range is again within the monitoring
range, "AL.14" will not be reported and "TEMP OUT" Output OFF continues.
State
⑦
: AL.14 report since 45 sec has elapsed since the circulating fluid temperature deviated,
because it is outside the upper temperature monitoring range. TEMP OUT output ON.
State
⑧
: The alarm is reset manually, the temperature monitoring upper and lower limit range is out,
so "AL.14", "AL.15" warning continue.
State
⑨
: Since it is within the temperature monitoring upper limit range, "TEMP OUT" output OFF
State
⑩
: Manual reset of alarm "AL.14", "AL.15" cancellation.
Low temperature limit of temperature range monitoring function
22.
Press the [▼] key. Displays Low temperature limit of temperature range monitoring
function setting screen.
For the function, refer to P.5-28 [Temperature range monitoring function setting example].
Monitoring of temperature range monitoring function
23.
Press the [▼] key. Displays monitoring of temperature range monitoring function
setting screen
Please select from the following items.
Set value
Contents
RNST
Monitoring during operation: The function is effective only
during operation.
PWON
Always Monitoring: The function is enabled even when
stopped (standby state).
For the function, refer to P.5-28 [Temperature range monitoring function
setting example].
RUN
℃
RUN
Monitoring of temperature range monitoring function
Low temperature limit of temperature range monitoring function
(
Setting range
:
5.0 to 40.0
℃
)
TEMP
⇒
OUT
⇒
LOTMP
(
Alternately displayed
)
TEMP
⇒
OUT
⇒
ALARM
(
Alternately displayed
)
Содержание HRR012-A*-20 Series
Страница 14: ...HRX OM W002 A Chapter 1 Safety Instructions 1 8 Material Safety Data Sheet MSDS HRR Series 1 8...
Страница 110: ...HRX OM W002 A Chapter 5 Display and Setting of Various Functions 5 5 Advanced setting mode HRR Series 5 62...
Страница 138: ...HRX OM W002 A Chapter 8 Control Inspection Exchange and Cleaning 8 5 Electrical schematic diagram HRR Series 8 18...
Страница 156: ...HRX OM W002 A Chapter 9 Documents 9 9 Daily Check HRR Series 9 18...
Страница 159: ......