![Smartgen HGMS62 Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/smartgen/hgms62/hgms62_user-manual_1297538039.webp)
HGMS62 Split Type Genset Controller User Manual Page 39 of 58
No.
Type
Function Description
112
Gen Over Volt Shut
Action when gen over voltage shutdown occurs.
113
Gen Under Freq. Warn
Action when gen under frequency warning occurs.
114
Gen Under Freq. Shut
Action when gen under frequency shutdown occurs.
115
Gen Under Volt Warn
Action when gen under voltage warning occurs.
116
Gen Under Volt Shut
Action when gen under voltage shutdown occurs.
117
Gen Loss of Phase
Action when gen losses phase.
118
Gen Reverse Phase Seq. Action when gen reverse phase sequence occurs.
119
Reserved
120
Over Power Alarm
Action when gen over power occurs.
121
Reserved
122
Reverse Power
Action when controller detects reverse power.
123
Over Current Alarm
Action when over current occurs.
124
Reserved
125
Mains Blackout
Action when mains can’t not be detected.
126
Mains Over Freq.
Action when mains over frequency warning occurs.
127
Mains Over Volt
Action when mains over voltage warning occurs.
128
Mains Under Freq.
Action when mains under frequency warning occurs.
129
Mains Under Volt
Action when mains under voltage warning occurs.
130
Mains Phase Seq. Error
Action in mains sequence is wrong.
131
Mains Loss of Phase
Action in mains phase lose.
132-
138
Reserved
139
High Temp Warn
Action when high temperature warning alarm occurs.
140
Low Temp Warn
Action when low temperature warning alarm occurs.
141
High Temp Shut
Action when high temperature shutdown alarm occurs.
142
Reserved
143
Low Oil Pressure Warn
Action when low oil pressure warning occurs.
144
Low Oil Pressure Shut
Action when low oil pressure shutdown occurs.
145
OP Sensor Open
Action when oil pressure sensor is open.
146
Reserved
147
Low Fuel Level
Action when controller issues low fuel level alarm.
148
Reserved
149
Reserved
150
Aux. Sensor 1 High Warn Action when aux. sensor 1 high warning occurs.
151
Aux. Sensor 1 Low Warn Action when aux. sensor 1 low warning occurs.
152
Aux. Sensor 1 High Shut
Action when aux. sensor 1 high shutdown occurs.
153
Aux. Sensor 1 Low Shut
Action when aux. sensor 1 low shutdown occurs.
154
Aux. Sensor 2 High Warn Action when aux. sensor 2 high warning occurs.
155
Aux. Sensor 2 Low Warn Action when aux. sensor 2 low warning occurs.
156
Aux. Sensor 2 High Shut
Action when aux. sensor 2 high shutdown occurs.
157
Aux. Sensor 2 Low Shut
Action when aux. sensor 2 low shutdown occurs.