ACC7200 Air Compressor Controller User Manual Page 52 of 77
No.
Type
Function Description
124 Flexible Sensor 6 Low Shut
Act when sensor 6 low shutdown occurs.
125 Urea Level Low Warning
Act when urea level low warning occurs.
126 Urea Level Low Shutdown
Act when urea level low shutdown occurs.
127 Flexible Sensor 7 High Warn Act when sensor 7 high warning occurs.
128 Flexible Sensor 7 Low Warn Act when sensor 7 low warning occurs.
129 Flexible Sensor 7 High Shut Act when sensor 7 high shutdown occurs.
130 Flexible Sensor 7 Low Shut
Act when sensor 7 low shutdown occurs.
131 Flexible Sensor 8 High Warn Act when sensor 8 high warning occurs.
132 Flexible Sensor 8 Low Warn Act when sensor 8 low warning occurs.
133 Flexible Sensor 8 High Shut Act when sensor 8 high shutdown occurs.
134 Flexible Sensor 8 Low Shut
Act when sensor 8 low shutdown occurs.
135 Reserved
136 Reserved
137 Reserved
138 Reserved
139 Reserved
8.2.2
CUSTOM PERIOD OUTPUT
Defined period output is composed by 2 parts: period output S1 and condition output S2.
S1 and S2 both are true, then it outputs; S1 or S2 is false, it doesn't output;
Period output S1 can be configured randomly to one, or several period outputs; Delay time and
output time after entering period can be set;
Condition output S2 can be any contents of output settings.
NOTE 1:
When period output S1 delay time and output time are both 0, configurations of period output S1 are both
true.
NOTE 2:
When selected period is ‘Standby’, it is cycle output and other periods are single output.
For example:
Output period: Start
Delay output time: 2s
Output time: 3s
Condition output contents: Input 1 is active;
Condition output active/inactive close; close when active (disconnect when inactive)
When input port 1 is active, and it enters start time and delays for 2s, custom period output starts to output, after
outputting for 3s, it stops outputting;
When input port 1 is inactive, custom output doesn't output.