ACC7200 Air Compressor Controller User Manual Page 40 of 77
No.
Item
Range
Default
Description
1: Active for Open
3
Active Range
(0-3)
2
0: From Safety On
1: From Crank
2: Always
3: Inactive
4
Active Action
(0-2)
0
0: Warning
1: Shutdown
2: Indication
5
Active Delay
(0-20.0)s
2.0
Time from detecting input
is active to confirm.
6
Input Description
Users defined.
Auxiliary Outputs
Auxiliary Output 1
1
Contents Setting
(0-139)
29
Fuel relay output;
Please refer to Table 11 for
details.
2
Output Type
(0-1)
0
0: Normally Open
1: Normally Close
Auxiliary Output 2
1
Contents Setting
(0-139)
28
Start relay output.
Please refer to Table 11 for
details.
2
Output Type
(0-1)
0
0: Normally Open
1: Normally Close
Auxiliary Output 3
1
Contents Setting
(0-139)
30
Idle speed control;
Please refer to Table 11 for
details.
2
Output Type
(0-1)
0
0: Normally Open
1: Normally Close
Auxiliary Output 4
1
Contents Setting
(0-139)
26
Load control;
Please refer to Table 11 for
details.
2
Output Type
(0-1)
0
0: Normally Open
1: Normally Close
Auxiliary Output 5
1
Contents Setting
(0-139)
39
Normal running output;
Please refer to Table 11 for
details.
2
Output Type
(0-1)
0
0: Normally Open
1: Normally Close
Auxiliary Output 6
1
Contents Setting
(0-139)
42
Common alarm;