ACC7200 Air Compressor Controller User Manual Page 26 of 77
No.
Item
Range
Default
Description
can change it to prevent others
changing lock status randomly;
Please remember the password
after the change, contact
factory personnel in case of
forgetting it.
2
Lock Set
(0-1)
0
0: Unlock 1: Lock
CAUTION:
After
lock,
controller displays Lock Mode
and compressor cannot be
started.
3
Speed Limit Set
(0-1)
0
0: No limit on user engine
speed setting.
1: Limit on the max. speed
set by user.
4
Default Config. Max. Speed
(0-6000)
2200
Limit on max. speed of the
corresponding
configuration, for example:
the default configuration of
the max. speed is set as
3000 and the speed limit is
set as enabled, when user
set engine rated speed, it
will not more than 3000.
5
Config. 1 Max. Speed
(0-6000)
2200
6
Config. 2 Max. Speed
(0-6000)
2200
7
Config. 3 Max. Speed
(0-6000)
2200
Module Setting
1
Module Address
(1-254)
1
Controller
address
for
remote monitoring.
2
Comm. Stop Bit
(0-1)
0
0: 2-bit Stop Bit
1: 1-bit Stop Bit (PC
software settings)
3
Password
(0-65535)
01234
It used for advanced
parameter setting;
CAUTION:
Default password
is “01234”; It can be changed by
users
for
purpose
of
predischarge others changing
the
controller
advanced
configurations.
Please
remember the password after
the change, contact factory
personnel in case of forgetting
it.
4
Maintenance Password
(0-65535)
01234
It is used for advanced
parameter settings;
CAUTION:
Default password