![Smartgen ACC7200 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/smartgen/acc7200/acc7200_user-manual_1297470011.webp)
ACC7200 Air Compressor Controller User Manual Page 11 of 77
4.2
CONTROLLER PANEL
Fig.1 ACC7200 Front Panel Indication
Table 5 Alarm Indicator
Alarms
Indicator
Warning
Slow Flash (once per second).
Shutdown
Fast Flash ( 5 times per second).
NOTE 1: Alarm Indicator: slow flash (once per second) for warning alarm; fast flash (5 times per second) for stop
alarm; light off for none alarm;
NOTE 2: Status Indicator: it illuminates always after air compressor starts successfully.
NOTE 3: Onload Indicator: after air compressor is started successfully, engine icon is lightened; press Onload key,
and when speed is up to load, onload control outputs and arrow indicators are enlightened; press Unload key, onload
control output is stopped and arrow indicators are off.
4.3
DISPLAY
4.31 MAIN DISPLAY
and
are used for screen scrolling. Press
key to enter user menu, press
key to return main display.
——
Homepage: engine speed, oil pressure, temperature, fuel level, discharge pressure of air
compressor, discharge temperature, battery voltage.
——
Sensor Information Page: charger voltage, measured information of all kinds of configurable
sensors.
——
ECU Information Page: if use the CANBUS port to read the engine information by J1939, the engine
information also includes: coolant pressure, coolant level, fuel temperature, fuel pressure, inlet
temperature, outlet temperature, turbine pressure, fuel consumption and total fuel consumption,
etc. (Different engines include the data that varies).
——
Accumulative Information Page: current running time, total running time, start times and CPU
temperature.
——
Engine Status Information Page: current status of engine and onload status.
——
Input/Output Status Page: emergency stop key and current status display of various digital