ACC7200 Air Compressor Controller User Manual Page 25 of 77
No.
Function
Cable Size
Remark
31
AUX. Input 9
1.0mm
2
Connects input COM.
32
AUX. Input 10
1.0mm
2
Connects input COM.
33
Input COM
1.0mm
2
Input COM, connects with battery
negative already inside.
34
AUX. Relay 10
1.5mm
2
N/C output, rated 8A.
Please see Table
11 for setting
items.
35
1.5mm
2
Relay COM.
36
1.5mm
2
N/C output, rated 8A.
37
Sensor COM
1.0mm
2
Sensor COM, connects with B- already inside.
38
DC5V
1.0mm
2
Power supply for voltage sensor.
39
Flexible Sensor 1
1.0mm
2
Users configurable (resistor).
40
Flexible Sensor 2
1.0mm
2
Users configurable (resistor).
41
Flexible Sensor 3
1.0mm
2
Users configurable (resistor).
42
Flexible Sensor 4
1.0mm
2
Users configurable (resistor/current/voltage).
43
Flexible Sensor 5
1.0mm
2
Users configurable (resistor/current/voltage).
44
Flexible Sensor 6
1.0mm
2
Users configurable (resistor/current/voltage).
45
Flexible Sensor 7
1.0mm
2
Users configurable (resistor/current/voltage).
46
Flexible Sensor 8
1.0mm
2
Users configurable (resistor/current/voltage).
USB HOST
/
Communication with U-disk.
USB DEVICE
/
Communication with PC monitoring software.
Note: The USB port on the back panel is the parameter programming port, the controller can be programmed by PC.
8
CONFIGURATION PARAMETER RANGE AND DEFINITION
8.1
PARAMETER SETTING CONTENTS AND RANGE
Table 10 Parameter Setting Contents and Range List
No.
Item
Range
Default
Description
Language
1
Language
(0-2)
0
0: Simplified Chinese
1: English
2: Others
Override Mode
1
Override Mode
(0-1)
0
0: Disable 1: Enable
LCD Backlight
1
Brightness
(0-5)
5
Set
LCD
backlight
brightness.
Compressor Lock Setting
1
Lock Password Set
(0-65535)
01234
This password is used for
entering Lock Set.
CAUTION:
Default factory
password is 01234; operator