SMA Solar Technology AG
Operation
Technical Description
SI5048-TEN093630
75
"Home Screen"
In the Home Screen, the Sunny Island also shows the following values in succession
(in 3-second intervals: parameter name and parameter value) in the upper line:
• Bar graph for output power or charging power (the direction of energy flow is displayed by the
arrows in the lower line)
• Total active power of the inverter (cluster)
• Active power of external source (total of all phases)
• Present state of charge of the battery (SOC)
• Counters (always one of five possibilities, depending on priority)
– remaining absorption time
– remaining generator warm up time
– Remaining Run1h time for the generator
– remaining time of Timer 1
– remaining time of Timer 2
• Active charging process
Position
Description
A
Output power/charging power (load status)
B
Direction of energy flow and system status
C
Grid status
D
Device assignment
E
Status of the external source (star, question mark or exclamation mark)
F
Relay 1 status
G
Relay 2 status
H
Warning message (exclamation mark)
Situation-Dependent Value Display
The values shown on the display are displayed or not depending on the situation. That is,
if there is no generator connected, no generator values are shown on the display.
Содержание SI 5048
Страница 1: ...SI5048 TEN093630 TBE SI5048 Version 3 0 EN Off grid Inverter SUNNY ISLAND 5048 Technical Description...
Страница 2: ......
Страница 10: ...Table of Contents SMA Solar Technology AG 10 SI5048 TEN093630 Technical Description...
Страница 43: ...SMA Solar Technology AG Electrical Connection Technical Description SI5048 TEN093630 43...
Страница 66: ...Operation SMA Solar Technology AG 66 SI5048 TEN093630 Technical Description Overview of the menu structure...
Страница 209: ......
Страница 210: ......
Страница 212: ...4 4PMBS 5FDIOPMPHZ XXX 4 EF...