Operation
SMA Solar Technology AG
68
SI5048-TEN093630
Technical Description
600# Direct Access - Direct access to the parameters
This is a main menu that gives you direct accesss to the settings and display values (see section
10.3 ”Direct Access (to the parameters)” (page 69)).
10.2 Changing Parameters
Using the up and down arrow buttons, you navigate through a selected menu to view or change a
parameter, for example. When the relevant parameter appears on the display, you can read its
present value.
An arrow next to the value indicates that the parameter can be changed.
If you press <ENTER>, the arrow begins to blink, and you can use the up and down arrow buttons to
change the value of the parameter.
As soon as the desired value appears on the display, press <ENTER> to save the new value.
Then select Y(es) or N(o) by pressing the up/down arrow buttons to accept or reject the changes.
Finally press <ENTER> again in order to finish the process and continue with other modifications.
The Sunny Island displays a corresponding message for parameters that can only be changed in
standby mode or require a different password level.
Increment size (speed)
The increment size (speed) of the change increases if you hold the button pressed down.
Changing parameters
Note that some parameters can only be changed when the device is in standby mode
(see section 9.2 ”Stopping the Sunny Island (Standby)” (page 61)). The parameters for
which this applies can be found in the tables in sections 19.2 ”Adjustable parameters”
(page 147) and 20 ”Troubleshooting” (page 184).
Display
Description
Incorrect password level, you cannot make any
changes in the menus. This is explained in section
10.5 ”Entering the installer password” (page 73).
This parameter can only be changed in standby
mode. Stop the Sunny Island to change the parameter
(see section 9.2 ”Stopping the Sunny Island
(Standby)” (page 61)).
Содержание SI 5048
Страница 1: ...SI5048 TEN093630 TBE SI5048 Version 3 0 EN Off grid Inverter SUNNY ISLAND 5048 Technical Description...
Страница 2: ......
Страница 10: ...Table of Contents SMA Solar Technology AG 10 SI5048 TEN093630 Technical Description...
Страница 43: ...SMA Solar Technology AG Electrical Connection Technical Description SI5048 TEN093630 43...
Страница 66: ...Operation SMA Solar Technology AG 66 SI5048 TEN093630 Technical Description Overview of the menu structure...
Страница 209: ......
Страница 210: ......
Страница 212: ...4 4PMBS 5FDIOPMPHZ XXX 4 EF...