133# Generator State
Number Name
Description
displayed
value
Description
01
GnDmdSrc
Source for generator request:
None
No request
Bat
Battery charge
state-dependent
Lod
Load-dependent
Tim
Time-controlled
Run1h
Requested for 1 hour
Start
Manual
ExtSrcReq Requested via an
external source
02
GnStt
Generator state
Off
Off
Init
Init
Ready
Waiting for request
(ready)
Warm
Warming up
Connect
Connecting
Run
Operation
Retry
Restarting
Disconnect Disconnecting
Cool
Cooling down
Lock
Locked after
operation
Fail
Error
FailLock
Locked after error
03
GnRmgTm
Remaining time of the generator
(Minimum running time in hours,
minutes and seconds)
04
GnRnStt
Status generator feedback master Off
off
On
On