Activation and Deactivation
SMA Solar Technology AG
62
SI5048-TEN093630
Technical Description
9.3 Switch off
To switch off the Sunny Island, proceed as follows:
1. Stop the Sunny Island as described in section 9.2 ”Stopping the Sunny Island (Standby)”
2. Switch the Sunny Island's DC circuit breaker to the "OFF" position.
☑ The Sunny Island is switched off.
9.4 Disconnect the device from voltage sources
1. Switch off the Sunny Island as described in section 9.3 ”Switch off” (page 62).
2. Disconnect the Sunny Island from the battery.
3. Disconnect the Sunny Island from the voltage sources (AC1 and AC2). Separate AC1 and AC2
and disconnect from voltage sources.
☑ If PV inverters are connected to AC1, these switch off automatically as soon as the island
grid is missing.
4. Check thatthe Sunny Island has been disconnected from voltage sources.
5. Wait at least 15 minutes to let the capacitors discharge and to allow the voltage inside the
device to drop to a safe level.
☑ The Sunny Island is free of voltage.
"Disconnection sequence"
Only with the sequence shown here can you ensure that all internal counter positions/
values are saved.
Содержание SI 5048
Страница 1: ...SI5048 TEN093630 TBE SI5048 Version 3 0 EN Off grid Inverter SUNNY ISLAND 5048 Technical Description...
Страница 2: ......
Страница 10: ...Table of Contents SMA Solar Technology AG 10 SI5048 TEN093630 Technical Description...
Страница 43: ...SMA Solar Technology AG Electrical Connection Technical Description SI5048 TEN093630 43...
Страница 66: ...Operation SMA Solar Technology AG 66 SI5048 TEN093630 Technical Description Overview of the menu structure...
Страница 209: ......
Страница 210: ......
Страница 212: ...4 4PMBS 5FDIOPMPHZ XXX 4 EF...