INTEGRATED FIREPLACE CONTROL (IFC)
Error codes
- All error codes are displayed on one a set of
three LEDs located beside the SW1 switch.
-
Low battery
: When backup battery is under 4V the RED LED
light (located beside the SW1 switch) will pulse steadily. A double
beep will be made by the IFC whenever a command is made
when backup batteries are below 4V.
-
Flame sense problem
: If the pilot flame is not detected or
the flame sense system is not satisfied the RED LED light will
pulse with 2 flashes until corrected.
-
Lockout
: If three trials for ignition fail the RED LED indicator
will pulse three times in intervals. To clear lockout power cycle
the IFC.