SUREFIRE ELECTRONIC IGNITION SYSTEM
S.I.T. PROFLAME 1 TROUBLESHOOTING
SimTech Proflame I
Black Plug for Modulator
Diagram 28
Continuity Test (Ohms)
Check the modulator for continuity. First test the orange and yellow wires at the contact points. Second, check
the black and brown wires. The reading should be approximately 26 ohms for each test
.
To Main Power Supply
Module On/Off Switch.
(This is in the Off position)
COM Port
120 vac outlet
Fan Outlet Only
Auxiliary Outlet
Only GTMF and GTMFS
Systems have this Module