24
24
SUREFIRE ELECTRONIC IGNITION SYSTEM
S.I.T. PROFLAME 1 TROUBLESHOOTING
SimTech Proflame I
Diagram 21
Check the batteries are installed correctly in the handheld transmitter (3 x AAA) and the receiver (4 x AA).
Diagram 22
Volts DC Test (VDC)
Check the battery voltage at #2 and #3 positions. While 4.4 vdc is the minimum voltage to operate it is recom-
mended to change the batteries at 5 vdc or lower.
Diagram 23
Check the remote wiring harness green and white wires marked TH -TH/TP are properly connected to the unit’s main
wiring harness marked ON/OFF.
Receiver Batteries
Remote Handheld
Plastic Harness (CN1)
Higher than 4.4 vdc. If reading is 5 vdc
or lower replace the batteries
Receiver Wires
Good Connections
Unit Wires
Содержание Maxitrol GV60
Страница 52: ...Diagram 19 52 SUREFIRE ELECTRONIC IGNITION SYSTEM S I T PROFLAME 2 TROUBLESHOOTING SimTech Proflame II...
Страница 53: ...MAXITROL GV60 TROUBLESHOOTING GUIDE 53 MAXITROL GV60 IGNITION SYSTEM TROUBLESHOOTING Maxitrol GV60...
Страница 70: ...70 July 2017 Product Specifications Book NOTES...