Linear Circuit Diagrams
IGNITION SHUTDOWN CIRCUIT
See Figures 12 and 13.
Ignition shutdown occurs when the ignition key switch is
turned to the “OFF” position or the safety system kills the
engine.
When the ignition shutdown occurs, the engine is
stopped by the following:
Air-Cooled Models – the magneto is grounded through
the ignition key switch (Figure 12).
Diesel Models – power is removed from the fuel injection
pump (Figure 13).
Liquid-Cooled Models – power is removed from the igni-
tion coil (Figure 13).
PTO CLUTCH CIRCUIT
See Figure 11.
The PTO clutch circuit becomes active only when the
PTO clutch is engaged, which occurs when the PTO
clutch switch is engaged (pulled up). Power to the PTO
clutch circuit comes from the ignition key switch when it
is in the “RUN” (ON) position.
When either PTO clutch switch is depressed the clutch is
energized, causing the clutch to engage and drive the
attachment connected to the tractor. When the PTO
clutch is engaged, the same power that is energizing the
clutch is connected to the PTO clutch indicator lamp on
the instrument panel.
NOTE: When there is not a rear PTO clutch installed,
jumpers will need to be installed on the connector for the
rear PTO clutch switch.
REAR
PTO SWITCH
(OFF POSITION)
N.O.
N.O. or N.C.
N.C .
BATTERY
CIRCUIT
BREAKER
A
M
L
G
B
S
FRONT
PTO SWITCH
(OFF POSITION)
N.O.
N.O. or N.C.
N.C .
JUMPER REQUIRED
WHEN REAR PTO
CLUTCH IS NOT
INSTALLED
KEY SWITCH
(ON POSITION)
FRONT
CLUTCH
REAR
CLUTCH
FRONT
PTO LAMP
REAR
PTO LAMP
Figure 11. Typical PTO Clutch Linear Circuit Diagram (All Models)
CHARGING CIRCUIT
See Figure 10.
The charging circuit is always active, regardless of the
position of the ignition switch. The charging circuit is
controlled and protected by the voltage regulator which is
housed in the alternator. The voltage regulator protects
the tractors electrical system by regulating the power
output of the alternator, preventing excessive current
draw and reverse power feed.
The alternator charges and equalizes the battery after
each start and supplies the tractors electrical devices
with power during operation.
BATTERY
CIRCUIT
BREAKER
ALTERNATOR
Figure 10. Typical Charging Linear Circuit Diagram
(All Models)
Not
for
Reproduction
Содержание AGCO Allis 2000 Series
Страница 1: ...USE N o t f o r R e p r o d u c t i o n...
Страница 18: ...1 16 1 General Information Notes N o t f o r R e p r o d u c t i o n...
Страница 24: ...2 Troubleshooting Notes 2 6 N o t f o r R e p r o d u c t i o n...
Страница 52: ...5 Belt Replacement Notes 5 6 N o t f o r R e p r o d u c t i o n...
Страница 101: ...7 33 7 Electrical System Service Troubleshooting Notes N o t f o r R e p r o d u c t i o n...
Страница 114: ...7 46 7 Electrical System Service Notes N o t f o r R e p r o d u c t i o n...
Страница 126: ...8 Power Steering Service Notes 8 12 N o t f o r R e p r o d u c t i o n...
Страница 162: ...11 Transaxle Removal Installation Notes 11 10 N o t f o r R e p r o d u c t i o n...
Страница 206: ...13 Engine Removal Installation Notes 13 36 N o t f o r R e p r o d u c t i o n...
Страница 244: ...17 Miscellaneous Component Service Notes 17 4 N o t f o r R e p r o d u c t i o n...
Страница 304: ...19 Implement Lift Service Notes 19 10 N o t f o r R e p r o d u c t i o n...
Страница 312: ...20 Power Steering Unit Service Notes 20 8 N o t f o r R e p r o d u c t i o n...