13. Hold the outside handle (3) and use the spanner to rotate the fastener
piece (5) about 75° to the right until it fits into position (Figures 4 and
5). If you do not fit it correctly, the handle may come loose again.
14. The inside fitting (8) is mounted onto the inner surface of the door. Push
the inside fitting spindle through the retainer slot in the mortise lock (6)
and push the inside fitting (8) onto the door until it is about 1 cm away.
15. Push the inside fitting's 3-pole cable through the locking cylinder open-
ing in the mortise lock.
16. Push the inside fitting (8) until it is flush with the door.
17. The outer fitting (4) is mounted from the outer side of the door.
18. Insert the lower spacing bolt (7) into the outer fitting (4); the upper spa-
cing bolt (7) is pre-fastened into position in the factory.
19. Push the outer fitting retainer slot onto the spindle while pushing the
two spacing bolts (7) through the drill holes in the door at the same
time. In doing so, ensure that the cable from the inside fitting does not
get caught.
20.Connect the 3-pole cable from the inside fitting to the 3-pole cable
from the outer fitting. This cable can only be inserted in one direction.
Do not pull on the cables while doing so; just carefully secure the plug-in
connection into position.
21. The 2-pole cable from the outer fitting can hang freely, but must not get
caught when the outer cover (2) is fitted. Do not pull on the cable.
22. Press outer and inside fittings together, so that they are both flush
against the door.
23. Press the electronics module cover lid in the inside fitting carefully out
of its bracket and fold back horizontally. Make sure that the electronics
are not subject to mechanical load and are not damaged in any other
way.
24.Carefully remove the upper battery (10) from the holder. Use clean
gloves free of fat or grease to handle batteries.
25. Insert the supplied screws (9) through drill holes in the inside fitting (8)
from inside the door and fasten to the spacing bolts (7) on the outer fit-
ting by hand, using about 5-7 Nm.
26.Insert the upper battery (10) with the positive terminals facing away
from the door into the brackets; in doing so, insert the batteries under
the black retaining collar first. Use clean gloves free of fat or grease to
handle batteries.
27. Lock the electronics cover lid back into place.
SmartHandle
SmartIntego
(Manual)
8. Installation (manual)
56 / 160
Содержание SI:SmartHandle Series
Страница 1: ...SmartHandle SmartIntego Manual 28 10 2020...
Страница 25: ...6 5 Distances and door thicknesses SmartHandle SmartIntego Manual 6 Designs 25 160...
Страница 131: ...SmartHandle SmartIntego Manual 8 Installation manual 131 160...
Страница 132: ...9 Outer fitting is mounted SmartHandle SmartIntego Manual 8 Installation manual 132 160...
Страница 136: ...2 Remove the uppermost battery SmartHandle SmartIntego Manual 8 Installation manual 136 160...
Страница 137: ...3 Screw on the inside fitting SmartHandle SmartIntego Manual 8 Installation manual 137 160...
Страница 141: ...3 Press the inside of the cover firmly SmartHandle SmartIntego Manual 8 Installation manual 141 160...
Страница 145: ...10 Configuration See TechGuide WO SVCN SmartHandle SmartIntego Manual 10 Configuration 145 160...
Страница 146: ...11 Status messages See TechGuide WO SVCN SmartHandle SmartIntego Manual 11 Status messages 146 160...
Страница 147: ...12 Signal See TechGuide WO SVCN SmartHandle SmartIntego Manual 12 Signal 147 160...