4.1.2 Operating Conditions
The following subsections define the operating conditions for the module.
4.1.2.1 General Operating Conditions
Table 4.2. General Operating Conditions
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
Operating temperature
range
T
OP
Ambient temperature range
-40
25
85
°C
VDD Operating supply volt-
age
V
VDD
DCDC in regulation
3.3
3.8
V
DCDC in bypass, 50mA load
1.85
3.3
3.8
V
VDD Current
I
VDD
DCDC in bypass
—
—
200
mA
HFCLK frequency
f
CORE
—
—
26
MHz
—
38.4
40
MHz
Note:
1. The minimum voltage required in bypass mode is calculated using R
BYP
from the DC-DC specification table. Requirements for
other loads can be calculated as V
VDD_min
+I
LOAD
* R
BYP_max
2. In MSC_READCTRL register
3. The minimum voltage of 2.4 V for DCDC is specified at 100 mA
BGM11S Blue Gecko
Bluetooth
®
SiP Module Data Sheet
Electrical Specifications
silabs.com
| Building a more connected world.
Rev. 1.0 | 17