The heater temperature control system for printing
The Printer receives the RIP data.
- The heaters become standby at the temperature below.
Preheater: 45 ºC
Printheater: 45 ºC
Afterheater: 60 ºC
However, the temperature above is lowered to the setup temperarure if the
setup temperature is lower than the standby temperature above.
Printheater set temperature
Preheater set temperature
Afterheater set temperature
Standby set temperature
Ambient temperature
Standby time
(Time)
(Temperature)
Set temperature maintained
Standby temperature maintained
Temperature control stop
Display the heater control menu.
Press the
HEATER
key to display the heater control menu.
Key operation in the heater control menu
and
keys
Select the heater whose temperature is to be set.
and
keys
Set the heater temperature.
M E N U
key
Turns the heater ON or OFF.
key
When this key is pressed for 1.5 seconds while the heater control menu
is displayed, all the heaters are forcibly turned on even without print
operation. (The heating control starts.)
CANCEL
key
Pressing this key for 1.5 seconds with the heater control menu displayed
cancels the heater-on state forcibly specified by the
key. (The heating
control stops.)
Finish displaying the heater control menu
Press the
HEATER
key while the heater control menu is displayed.
■
When the heater control menu display finishes automatically
H E A T E R D I S P L A Y E N D
If no key is input for 30 seconds while the heater control menu is displayed, a message "HEATER DISPLAY END"
appears automatically for two seconds and then the heater control menu display finishes. While this message is
displayed, no key input is effective.