PowerSync Analyzer Reference Manual
March 9, 2010
Sifos Technologies page
82
The Multi-Port Test sequencer command also takes the commonly used test resource specification argument utilized by
the individual Multi-Port tests. The following additional parameters also apply to the Multi-Port sequencing command.
Note that many of these carry over from optional arguments to individual Multi-Port tests.
Command
Command Parameters
<
-t
{
testList
} |
-e
{
testList
} >
<
-s
|
-f
<
-n
file_name
> >
<
-det
Sig_Load
>
<
-it
Transient_Load
> <
-dt
Transient_Time
>
<
-dur
Test_Time
> <
disconnect
>
<
-imin
Imin1
>
<
-icu
t
Icut
>
multiport
Automatically sequences one or more Multi-Port tests and produces a test report.
-t
Specify one or more tests to run. Default is ALL tests.
-e
Specify one or more tests to exclude. Default is NO tests exclusions.
testList
List of tests to sequence or exclude. At most, include one instance of each test.
-s
Develop standard spreadsheet report using mp_report.xls.
-f
Develop text report using time-date based file name.
-n
Override standard text report file name with user specified
file_name
.
-det
Specify a detection signature load to emulate in
mp_pwrup_
tests.
Sig_Load
Detection signature= mid | low | high. See
mp_pwrup_ports
command.
-it
Specify non-default transient load current to apply in
mp_iso_
tests.
Transient_Load
Transient load current in mA. See
mp_iso_1port
and
mp_iso_nport
commands.
-dt
Specify non-default transient transient duration to apply in
mp_iso_
tests.
Transient_Time
Transient load duration in msec. See
mp_iso_1port
and
mp_iso_nport
commands.
-dur
Specify non-default test time in units of minutes to
mp_dur_
tests.
Test_Time
Test time to utilize for PSE stress test. Range is 1 to 6000 (minutes).
Default is 10 minutes.
disconnect
Control to disconnect from any test ports that are found to have shut down. See
mp_dur_static
and
mp_dur_cycle
commands.
-imin
Specify a non-default PSE disconnect shut-down current to
mp_discx_
tests.
Imin1
Disconnect shutdown current level Imin1. See
mp_discx_
commands.
-icut
Specify a non-default PSE overload current (Icut) to
mp_overld_
tests.
Icut
PSE overload shutdown current (Icut). See
mp_overld_
commands.
Note:
Arguments associated with the tests
mp_iso_1port
and
mp_iso_nport
are only valid with the
PSA-1200 and PSA-2400 platforms.
An example of the
multiport
command (PD class 2 emulation) with output to spreadsheet report would be:
multiport
192.168.221.105 allports 192.168.221.106 slots 1-6 –c 2 –s
To run a subset of tests with high detection signature, PD class 3 emulation, and spreadsheet reporting:
multiport
192.168.221.107 allports –t {mp_pwrup_ports mp_cap_pwr} –c 3 –det high
–s
Содержание PowerSync PSA100
Страница 26: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 26 ...
Страница 56: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 56 ...
Страница 84: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 84 ...
Страница 110: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 110 ...
Страница 120: ...PowerSync Analyzer Reference Manual March 9 2010 Sifos Technologies page 120 ...