Table of contents
SIVACON 8PS - Configuring with LX system
Configuration Manual, 10/2011, A5E02194899-02
5
7
Technical data ....................................................................................................................................... 125
7.1
LX general data..........................................................................................................................125
7.2
Trunking units LXA..30 (aluminium)...........................................................................................126
7.3
Trunking units LXA..41 (aluminium)...........................................................................................128
7.4
Trunking units LXA..51 (aluminium)...........................................................................................130
7.5
Trunking units LXA..52 (aluminium)...........................................................................................132
7.6
Trunking units LXA..61 (aluminium)...........................................................................................134
7.7
Trunking units LXA..62 (aluminium)...........................................................................................136
7.8
Trunking units LXC..30 (copper)................................................................................................138
7.9
Trunking units LXC..41 (copper)................................................................................................140
7.10
Trunking units LXC..51 (copper)................................................................................................142
7.11
Trunking units LXC..52 (copper)................................................................................................144
7.12
Trunking units LXC..53 (copper)................................................................................................146
7.13
Trunking units LXC..54 (copper)................................................................................................148
7.14
Trunking units LXC..61 (copper)................................................................................................150
7.15
Trunking units LXC..62 (copper)................................................................................................152
7.16
Fire load for trunking units without tap-off points.......................................................................154
7.17
Fixing distances .........................................................................................................................155
7.18
Connection units for non-Siemens distribution boards ..............................................................155
7.19
Tap-off units ...............................................................................................................................156
8
Dimension drawings .............................................................................................................................. 159
8.1
Straight trunking units ................................................................................................................159
8.1.1
Straight trunking units with tap-off points...................................................................................159
8.1.2
Straight trunking units without tap-off points..............................................................................160
8.1.3
Straight trunking units with expansion compensation................................................................161
8.2
Junction units .............................................................................................................................162
8.3
Feeder units ...............................................................................................................................164
8.3.1
Universal busbar connection units.............................................................................................164
8.3.1.1 Universal busbar connection unit AS1.......................................................................................164
8.3.1.2 Universal busbar connection unit AS3.......................................................................................165
8.3.1.3 Universal busbar connection unit AS2.......................................................................................166
8.3.1.4 Universal busbar connection unit AS1 with T tap-off unit ..........................................................167
8.3.1.5 Universal busbar connection unit AS3 with T tap-off unit ..........................................................168
8.3.1.6 Universal busbar connection unit AS2 with T tap-off unit ..........................................................169
8.3.1.7 Connection tags .........................................................................................................................170
8.3.2
Incoming cable connection units................................................................................................173
8.3.3
Non-Siemens distribution board connection units .....................................................................175
8.3.4
Distribution board connection units............................................................................................182
Содержание SIVACON 8PS
Страница 2: ......
Страница 206: ...Glossary SIVACON 8PS Configuring with LX system 204 Configuration Manual 10 2011 A5E02194899 02 ...
Страница 209: ......