ATEX/IECEx and others
SITRANS TH/TR
SITRANS TF
Display
ABNT NBR IEC60079-0
ERRATA 2:2016
ABNT NBR IEC60079-1
:2016
ABNT NBR IEC60079-3
1:2014
-
DEK xx.00xxX
-
ГОСТ 31610.0-2014
(IEC 60079-0:2011)
ГОСТ 31610.1.1-2012
(IEC 60079-1:2002)
ГОСТ xxxxx.xx-xxxx/
IEC 60079-31:2013
-
№ TC RU C–DE.xxxx.x.xxxxxОС
НАНИО «ЦСВЭ»
-
• "Intrinsic safety ia/ib"
type of protection
Zones 0, 1, 2, 20, 21, 22 and M1
Name
• ATEX
II 1 G Ex ia IIC T6 ... T4 Ga
II 2(1) G Ex ib [ia Ga] IIC T6 ... T4 Gb
II 1 D Ex ia IIIC Da
I M1 Ex ia I Ma
II 1 G Ex ia IIC T6 ... T4 Ga
II 1 D Ex ia IIIC Da
I M1 Ex ia I Ma
• IECEx and others
Ex ia IIC T6 ... T4 Ga
Ex ib [ia Ga] IIC T6 ... T4 Gb
Ex ia IIIC Da
Ex ia I Ma
Ex ia IIC T6 ... T4 Ga
Ex ia IIIC Da
Ex ia I Ma
• EACEx
0Ex ia IIC T6 ... T4 Ga Х
1Ex ib [ia Ga] IIC T6 ... T4 Gb Х
Ex ia IIIC T70 °С to T105 °С Da Х
РО Ех ia I Ma X
0Ex ia IIC T6 ... T4 Ga Х
Ex ia IIIC Da Х
PO Ex ia I Ma Х
Output terminals
SITRANS TH/
SITRANS TF single
chamber housing: 1, 2
SITRANS TR: 3, 4
SITRANS TF dual cham‐
ber housing: (+) and (-)
U
i
= 30 V DC, I
i
= 120 mA, L
i
=
0 μH, C
i
= 1.0 nF
U
i
= 30 V DC, I
i
= 120 mA, L
i
=
0 μH, C
i
= 2.2 nF
U
i
= 30 V DC, I
i
= 120 mA, L
i
=
0 μH, C
i
= 2.2 nF
• Permissible ambi‐
ent temperature P
i
= 900 mW
-50 °C to +85 °C
(-58 °F to +185 °F) temperature
class T4
-50 °C to +65 °C
(-58 °F to +149 °F) temperature
class T5
-50 °C to +50 °C
(-58 °F to +122 °F) temperature
class T6
Single cham‐
ber housing
-50 … +75 °C
(-58 … +167 °F
) T4
1)
-50 … +40 °C
(-58 … +104 °F
) T6
1)
Dual chamber
housing
-50 … +75 °C
(-58 … +167 °F
) T4
1)
-50 … +40 °C
(-58 … +104 °F
) T6
1)
-40 °C to +85 °C
(-40 °F to +185 °F) temperature
class T4
-40 °C to +65 °C
(-40 °F to +149 °F) temperature
class T5
-40 °C to +50 °C
(-40 °F to +122 °F) temperature
class T6
• Permissible ambi‐
ent temperature P
i
= 750 mW
-50 °C to +85 °C
(-58 °F to +185 °F) temperature
class T4
-50 °C to +70 °C
(-58 °F to +158 °F) temperature
class T5
-50 °C to +55 °C
(-58 °F to +131 °F) temperature
class T6
-50 … +75 °C (-58 … +167 °F)
Temperature class T4
1)
-50 … +45 °C (-58 … +113 °F)
Temperature class T6
1)
-40 °C to +85 °C
(-40 °F to +185 °F) temperature
class T4
-40 °C to +70 °C
(-40 °F to +158 °F) temperature
class T5
-40 °C to +55 °C
(-40 °F to +131°F) temperature
class T6
Technical data
12.2 SITRANS TH320/TH420/TR320/TR420/TF320/TF420
SITRANS TH100/TH320/TH420/TR320/TR420/TF320/TF420 with 4 to 20 mA/HART
Operating Instructions, 05/2020, A5E41864807-AB
205