Basic values
Input type
Basic accuracy
Temperature coefficient
1)
TC E
≤ ±0.2 °C
≤ ± 0.01% of the value
≤ ±0.025 °C/°C
TC J
≤ ±0.25 °C
≤ ± 0.01% of the value
≤ ±0.025 °C/°C
TC K
≤ ±0.25 °C
≤ ± 0.01% of the value
≤ ±0.025 °C/°C
TC L
≤ ±0.35 °C
≤ ± 0.01% of the value
≤ ±0.025 °C/°C
TC N
≤ ±0.4 °C
≤ ± 0.01% of the value
≤ ±0.025 °C/°C
TC T
≤ ±0.25 °C
≤ ± 0.01% of the value
≤ ±0.025 °C/°C
TC U
< 0 °C ≤ ±0.8 °C
≤ ± 0.01% of the value
≥ 0 °C ≤ ±0.4 °C
≤ ± 0.01% of the value
≤ ±0.025 °C/°C
TC Lr
≤ ±0.2 °C
≤ ± 0.01% of the value
≤ ±0.1 °C/°C
TC R
< 200 °C ≤ ±0.5 °C
≤ ± 0.01% of the value
≥ 200 °C ≤ ±1 °C
≤ ± 0.01% of the value
≤ ±0.1 °C/°C
TC S
< 200 °C ≤ ±0.5 °C
≤ ± 0.01% of the value
≥ 200 °C ≤ ±1 °C
≤ ± 0.01% of the value
≤ ±0.1 °C/°C
TC W3
≤ ±0.6 °C
≤ ± 0.01% of the value
≤ ±0.1 °C/°C
TC W5
≤ ±0.4 °C
≤ ± 0.01% of the value
≤ ±0.1 °C/°C
TC type: B
2)
≤ ±1 °C
≤ ± 0.01% of the value
≤ ±0.1 °C/°C
TC type: B
3)
≤ ±3 °C
≤ ± 0.01% of the value
≤ ±0.1 °C/°C
TC type: B
4)
≤ ±8 °C
≤ ± 0.01% of the value
≤ ±0.8 °C/°C
TC type: B
5)
Not specified
Not specified
CJC (internal)
< ± 0.5 °C
Included in basic accuracy
CJC (external)
≤ ±0.08 °C
≤ ±0.002 °C/°C
1)
Temperature coefficients of the inputs correspond to the specified values or 0.002% of the input span,
depending on which value is greater.
Technical data
12.2 SITRANS TH320/TH420/TR320/TR420/TF320/TF420
SITRANS TH100/TH320/TH420/TR320/TR420/TF320/TF420 with 4 to 20 mA/HART
Operating Instructions, 05/2020, A5E41864807-AB
199