8.16
Commissioning the USB modem and SIPROM T
8.16.1
Fundamental safety instructions
NOTICE
Improper operating conditions
Device damage.
• Only operate the USB modem under laboratory conditions.
• Observe the environmental requirements in section Technical data (Page 193).
• Only operate the USB modem in a controlled electromagnetic environment. Do not use
radio transmitters, such as mobile phones, in the direct vicinity.
• Do not expose the modem to moisture or direct sunlight.
8.16.2
Installing the SIPROM T parameterization software
Requirement
• PC with USB port and Windows 10 operating system
• Windows Microsoft .NET Framework 4.5 or higher for Windows 10
• USB modem present
Procedure
1. Download the SIPROM T parameter assignment software from the Internet free of charge.
http://www.siemens.com/processinstrumentation/downloads
)
2. Uninstall the SIPROM T installations from your PC.
3. Before you start the installation, read the information for preparation in the Readme file.
4. Double-click the "setup.exe" file in the SIPROM T software directory.
5. Follow the installation instructions.
6. Download the following USB driver from the Internet: (
Drivers/CDM/CDM20830_Setup.exe
7. Open the USB driver file.
8. Install the downloaded USB driver.
Commissioning
8.16 Commissioning the USB modem and SIPROM T
SITRANS TH100/TH320/TH420/TR320/TR420/TF320/TF420 with 4 to 20 mA/HART
Operating Instructions, 05/2020, A5E41864807-AB