![Siemens SITRANS LR200 7ML5422 Скачать руководство пользователя страница 33](http://html.mh-extra.com/html/siemens/sitrans-lr200-7ml5422/sitrans-lr200-7ml5422_operating-instructions-manual_384663033.webp)
SITRANS LR200 with mA/HART
Operating Instructions, 05/2019, A5E32337676-AE
33
5.3
Nameplates for hazardous area installations
There are six wiring options for hazardous area installations:
●
Intrinsically Safe wiring (Page 33)
●
Non-Sparking wiring
●
Non-incendive wiring (US/Canada only)
●
Flameproof wiring
●
Increased safety wiring
●
Explosion-proof wiring (US/Canada only)
In all cases, check the nameplate on your instrument, confirm the approval rating, and
perform installation and wiring according to your local safety codes.
For installation across Zone 0 and Zone 1 boundary:
①
Threaded nut acts as partition wall
Material: Stainless steel, aluminium, and potting compound (hardness of at least 88 SHORE D;
compressive strength of at least 14,000 psi)
②
Zone 1
③
Zone 0
5.3.1
Intrinsically Safe wiring
5.3.1.1
Device nameplate (ATEX/IECEX/INMETRO/RCM)
①
The ATEX certificate can be downloaded from the product page of our website at
www.siemens.com/LR200 (
). Go to Support > Approvals / Certifi-
cates.
The IECEx certificate listed on the nameplate can be viewed on the IECEx website. Go to:
http://iecex.iec.ch (
) and click on Ex Equipment Certificates of Conformity
then enter the certificate number IECEx SIR 13.0006X.
Содержание SITRANS LR200 7ML5422
Страница 185: ...SITRANS LR200 with mA HART Operating Instructions 05 2019 A5E32337676 AE 185 B 5 4 PFTE rod antenna threaded connection ...
Страница 193: ...SITRANS LR200 with mA HART Operating Instructions 05 2019 A5E32337676 AE 193 ...
Страница 194: ...SITRANS LR200 with mA HART 194 Operating Instructions 05 2019 A5E32337676 AE ...
Страница 212: ...Index SITRANS LR200 with mA HART 212 Operating Instructions 05 2019 A5E32337676 AE ...