![Siemens SITRANS LR200 7ML5422 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/siemens/sitrans-lr200-7ml5422/sitrans-lr200-7ml5422_operating-instructions-manual_384663023.webp)
Installing/mounting
4.2 Mounting
SITRANS LR200 with mA/HART
Operating Instructions, 05/2019, A5E32337676-AE
23
4.2.1.2
Nozzle location
Beam angle
●
Beam angle is the width of the cone where the energy density is half of the peak energy
density.
●
The peak energy density is directly in front of and in line with the rod antenna.
●
There is a signal transmitted outside the beam angle, therefore false targets may be
detected.
①
Min. 300 mm (1 ft) per 3 m (10') of vessel height
②
Emission cone
③
Beam angle 28°
Emission cone
●
Keep emission cone free of interference from ladders, pipes, I-beams or filling streams.
●
Locate the antenna away from the side wall, to avoid interference from indirect echoes.
●
Make allowance for the emission cone spreading: allow a minimum of 300 mm (1 ft) for
every 3 m (10 ft) of vessel height.
Содержание SITRANS LR200 7ML5422
Страница 185: ...SITRANS LR200 with mA HART Operating Instructions 05 2019 A5E32337676 AE 185 B 5 4 PFTE rod antenna threaded connection ...
Страница 193: ...SITRANS LR200 with mA HART Operating Instructions 05 2019 A5E32337676 AE 193 ...
Страница 194: ...SITRANS LR200 with mA HART 194 Operating Instructions 05 2019 A5E32337676 AE ...
Страница 212: ...Index SITRANS LR200 with mA HART 212 Operating Instructions 05 2019 A5E32337676 AE ...